imx_thermal.c: Use old trip point values from BSP 2.7toradex_4.9-1.0.x-imx-rebased
In kernel upgrade from 4.1 -> 4.9 trip point values have been changed
by NXP. These new values caused a lot of modules to critical shut-down
during validation and verification. This commit changes the new
imx_thermal.c code to use the old, well verified values.
Signed-off-by: Philippe Schenker <philippe.schenker@toradex.com>
Acked-by: Max Krummenacher <max.krummenacher@toradex.com>
(cherry picked from commit 308edefe57c5c96fad196b6e65fa159857e969f3)
-rw-r--r-- | drivers/thermal/imx_thermal.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 449d0fb0ce36..b44123d6017b 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -659,7 +659,7 @@ static int imx_get_sensor_data(struct platform_device *pdev) * Set the critical trip point at 5C under max * Set the passive trip point at 10C under max (can change via sysfs) */ - data->temp_critical = data->temp_max - (1000 * 5); + data->temp_critical = data->temp_max + (1000 * 10); data->temp_passive = data->temp_max - (1000 * 10); return 0; |