diff options
author | Jan Kiszka <jan.kiszka@siemens.com> | 2019-09-04 08:42:30 +0200 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2019-11-10 11:34:56 +0100 |
commit | 036fb5dc7c9e4c1fd75be4ff95861c7b74168ebb (patch) | |
tree | a598d67626f4363dfb68021f3d68a4f92e0346a9 | |
parent | 76b4d8952ff119a143c25159bbf58417f2b548b4 (diff) |
platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
commit ad0d315b4d4e7138f43acf03308192ec00e9614d upstream.
The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-rw-r--r-- | drivers/platform/x86/pmc_atom.c | 7 |
1 files changed, 7 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index aa53648a2214..9aca5e7ce6d0 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_BOARD_NAME, "CB6363"), }, }, + { + .ident = "SIMATIC IPC227E", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), + DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"), + }, + }, { /*sentinel*/ } }; |