summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorWolfram Sang <w.sang@pengutronix.de>2009-11-16 12:57:50 +0000
committerDavid S. Miller <davem@davemloft.net>2009-11-17 03:54:03 -0800
commit3f158c253214bb783e7072f6848b61c1999631e7 (patch)
treedd0cb414b696df9c6a65d302621f142c44389708
parent68bd7422a2e07a4e5502137cd4bddb8c2774a912 (diff)
net/can/mpc52xx_can: refactor clock-get routine
Merge two functions into one. The result is smaller as they can now share some variables. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r--drivers/net/can/mscan/mpc52xx_can.c45
1 files changed, 16 insertions, 29 deletions
diff --git a/drivers/net/can/mscan/mpc52xx_can.c b/drivers/net/can/mscan/mpc52xx_can.c
index 34ae2baec5d1..a915959b6b36 100644
--- a/drivers/net/can/mscan/mpc52xx_can.c
+++ b/drivers/net/can/mscan/mpc52xx_can.c
@@ -38,28 +38,37 @@
static struct of_device_id mpc52xx_cdm_ids[] __devinitdata = {
{ .compatible = "fsl,mpc5200-cdm", },
- { .compatible = "fsl,mpc5200b-cdm", },
{}
};
/*
- * Get the frequency of the external oscillator clock connected
- * to the SYS_XTAL_IN pin, or return 0 if it cannot be determined.
+ * Get frequency of the MSCAN clock source
+ *
+ * Either the oscillator clock (SYS_XTAL_IN) or the IP bus clock (IP_CLK)
+ * can be selected. According to the MPC5200 user's manual, the oscillator
+ * clock is the better choice as it has less jitter but due to a hardware
+ * bug, it can not be selected for the old MPC5200 Rev. A chips.
*/
-static unsigned int __devinit mpc52xx_can_xtal_freq(struct of_device *of)
+
+static unsigned int __devinit mpc52xx_can_clock_freq(struct of_device *of,
+ int clock_src)
{
+ unsigned int pvr;
struct mpc52xx_cdm __iomem *cdm;
struct device_node *np_cdm;
unsigned int freq;
u32 val;
+ pvr = mfspr(SPRN_PVR);
+
freq = mpc5xxx_get_bus_frequency(of->node);
if (!freq)
return 0;
- /*
- * Determine SYS_XTAL_IN frequency from the clock domain settings
- */
+ if (clock_src == MSCAN_CLKSRC_BUS || pvr == 0x80822011)
+ return freq;
+
+ /* Determine SYS_XTAL_IN frequency from the clock domain settings */
np_cdm = of_find_matching_node(NULL, mpc52xx_cdm_ids);
if (!np_cdm) {
dev_err(&of->dev, "can't get clock node!\n");
@@ -80,28 +89,6 @@ static unsigned int __devinit mpc52xx_can_xtal_freq(struct of_device *of)
return freq;
}
-/*
- * Get frequency of the MSCAN clock source
- *
- * Either the oscillator clock (SYS_XTAL_IN) or the IP bus clock (IP_CLK)
- * can be selected. According to the MPC5200 user's manual, the oscillator
- * clock is the better choice as it has less jitter but due to a hardware
- * bug, it can not be selected for the old MPC5200 Rev. A chips.
- */
-
-static unsigned int __devinit mpc52xx_can_clock_freq(struct of_device *of,
- int clock_src)
-{
- unsigned int pvr;
-
- pvr = mfspr(SPRN_PVR);
-
- if (clock_src == MSCAN_CLKSRC_BUS || pvr == 0x80822011)
- return mpc5xxx_get_bus_frequency(of->node);
-
- return mpc52xx_can_xtal_freq(of);
-}
-
static int __devinit mpc5xxx_can_probe(struct of_device *ofdev,
const struct of_device_id *id)
{