There is an error in the report descriptor of the Thinkpad Helix 2 where logical minimum value (557376) is greater than logical maximum (491200) for all of the magnetic flux axis data fields. This error results in a report descriptor parsing failure that causes the sensors attached to the hub not to be detected. dmesg excerpt: [ 19.866905] drivers/hid/hid-core.c: logical range invalid 0x88140 0x77ec0 [ 19.866914] hid-sensor-hub 0018:2047:0855.0007: item 0 1 0 8 parsing failed [ 19.866926] hid-sensor-hub 0018:2047:0855.0007: parse failed [ 19.866933] hid-sensor-hub: probe of 0018:2047:0855.0007 failed with error -22 Add a report fixup to change magnetic flux logical minimums to -557376 for the parsing to succeed and the sensors to get detected. After applying the fix the sensors get detected, with corresponding drivers (hid-accel-3d,hid-gyro-3d,etc) loaded, and its possible to read their values. Signed-off-by: Fernando D S Lima <fernandodsl@gmail.com> Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>