dt-bindings: connector: Add support for USB-PD PPS APDOs to bindings
Add support for PPS APDOs to connector bindings so a port controller can specify support for PPS, as per existing FIXED/BATT/VAR PDOs. Signed-off-by: Adam Thomson <Adam.Thomson.Opensource@diasemi.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'Documentation/devicetree/bindings/connector')
-rw-r--r--Documentation/devicetree/bindings/connector/usb-connector.txt8
1 files changed, 4 insertions, 4 deletions
diff --git a/Documentation/devicetree/bindings/connector/usb-connector.txt b/Documentation/devicetree/bindings/connector/usb-connector.txt
index 8855bfcfd778..d90e17e2428b 100644
--- a/Documentation/devicetree/bindings/connector/usb-connector.txt
+++ b/Documentation/devicetree/bindings/connector/usb-connector.txt
@@ -29,15 +29,15 @@ Required properties for usb-c-connector with power delivery support:
in "Universal Serial Bus Power Delivery Specification" chapter 6.4.1.2
Source_Capabilities Message, the order of each entry(PDO) should follow
the PD spec chapter 6.4.1. Required for power source and power dual role.
- User can specify the source PDO array via PDO_FIXED/BATT/VAR() defined in
- dt-bindings/usb/pd.h.
+ User can specify the source PDO array via PDO_FIXED/BATT/VAR/PPS_APDO()
+ defined in dt-bindings/usb/pd.h.
- sink-pdos: An array of u32 with each entry providing supported power
sink data object(PDO), the detailed bit definitions of PDO can be found
in "Universal Serial Bus Power Delivery Specification" chapter 6.4.1.3
Sink Capabilities Message, the order of each entry(PDO) should follow
the PD spec chapter 6.4.1. Required for power sink and power dual role.
- User can specify the sink PDO array via PDO_FIXED/BATT/VAR() defined in
- dt-bindings/usb/pd.h.
+ User can specify the sink PDO array via PDO_FIXED/BATT/VAR/PPS_APDO() defined
+ in dt-bindings/usb/pd.h.
- op-sink-microwatt: Sink required operating power in microwatt, if source
can't offer the power, Capability Mismatch is set. Required for power
sink and power dual role.