summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/devfreq
diff options
context:
space:
mode:
authorDmitry Osipenko <digetx@gmail.com>2021-06-01 05:23:19 +0300
committerChanwoo Choi <cw00.choi@samsung.com>2021-06-17 17:08:57 +0900
commit6b61f55ecbe693d9d0d7ae14ebce01dabe10ecf1 (patch)
tree6a3ddfb1025cc43f27e8dc251d5b2742fac38c41 /Documentation/devicetree/bindings/devfreq
parent271ca53cb0c8b3a45c73e1140fc3336c2da42315 (diff)
dt-bindings: devfreq: tegra30-actmon: Add cooling-cells
The ACTMON watches activity of memory clients. Decisions about a minimum required frequency are made based on the info from ACTMON. We can use ACTMON as a thermal cooling device by limiting the required frequency. Document new cooling-cells property of NVIDIA Tegra ACTMON hardware unit. Reviewed-by: Rob Herring <robh@kernel.org> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Acked-by: Thierry Reding <treding@nvidia.com> Signed-off-by: Dmitry Osipenko <digetx@gmail.com> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Diffstat (limited to 'Documentation/devicetree/bindings/devfreq')
-rw-r--r--Documentation/devicetree/bindings/devfreq/nvidia,tegra30-actmon.yaml5
1 files changed, 5 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/devfreq/nvidia,tegra30-actmon.yaml b/Documentation/devicetree/bindings/devfreq/nvidia,tegra30-actmon.yaml
index ba938eed28ee..e3379d106728 100644
--- a/Documentation/devicetree/bindings/devfreq/nvidia,tegra30-actmon.yaml
+++ b/Documentation/devicetree/bindings/devfreq/nvidia,tegra30-actmon.yaml
@@ -63,6 +63,9 @@ properties:
Should contain freqs and voltages and opp-supported-hw property, which
is a bitfield indicating SoC speedo ID mask.
+ "#cooling-cells":
+ const: 2
+
required:
- compatible
- reg
@@ -74,6 +77,7 @@ required:
- interconnects
- interconnect-names
- operating-points-v2
+ - "#cooling-cells"
additionalProperties: false
@@ -118,4 +122,5 @@ examples:
operating-points-v2 = <&dvfs_opp_table>;
interconnects = <&mc TEGRA30_MC_MPCORER &emc>;
interconnect-names = "cpu-read";
+ #cooling-cells = <2>;
};