summaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings
diff options
context:
space:
mode:
authorDavid Daney <david.daney@cavium.com>2012-06-27 07:33:38 +0000
committerDavid S. Miller <davem@davemloft.net>2012-06-27 21:23:25 -0700
commite9976d7c96423ac1991396aa82335206ded55bcf (patch)
tree394e2e0964b90e42e0f638b6fad6c1362a737d14 /Documentation/devicetree/bindings
parenta30e2c1891296b5ee8de48430a07fdf8b818c661 (diff)
netdev/phy: Add driver for Broadcom BCM87XX 10G Ethernet PHYs
Add a driver for BCM8706 and BCM8727 devices. These are a 10Gig PHYs which use MII_ADDR_C45 addressing. They are always 10G full duplex, so there is no autonegotiation. All we do is report link state and send interrupts when it changes. If the PHY has a device tree of_node associated with it, the "broadcom,c45-reg-init" property is used to supply register initialization values when config_init() is called. Signed-off-by: David Daney <david.daney@cavium.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'Documentation/devicetree/bindings')
-rw-r--r--Documentation/devicetree/bindings/net/broadcom-bcm87xx.txt29
1 files changed, 29 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/net/broadcom-bcm87xx.txt b/Documentation/devicetree/bindings/net/broadcom-bcm87xx.txt
new file mode 100644
index 000000000000..7c86d5e28a0e
--- /dev/null
+++ b/Documentation/devicetree/bindings/net/broadcom-bcm87xx.txt
@@ -0,0 +1,29 @@
+The Broadcom BCM87XX devices are a family of 10G Ethernet PHYs. They
+have these bindings in addition to the standard PHY bindings.
+
+Compatible: Should contain "broadcom,bcm8706" or "broadcom,bcm8727" and
+ "ethernet-phy-ieee802.3-c45"
+
+Optional Properties:
+
+- broadcom,c45-reg-init : one of more sets of 4 cells. The first cell
+ is the MDIO Manageable Device (MMD) address, the second a register
+ address within the MMD, the third cell contains a mask to be ANDed
+ with the existing register value, and the fourth cell is ORed with
+ he result to yield the new register value. If the third cell has a
+ value of zero, no read of the existing value is performed.
+
+Example:
+
+ ethernet-phy@5 {
+ reg = <5>;
+ compatible = "broadcom,bcm8706", "ethernet-phy-ieee802.3-c45";
+ interrupt-parent = <&gpio>;
+ interrupts = <12 8>; /* Pin 12, active low */
+ /*
+ * Set PMD Digital Control Register for
+ * GPIO[1] Tx/Rx
+ * GPIO[0] R64 Sync Acquired
+ */
+ broadcom,c45-reg-init = <1 0xc808 0xff8f 0x70>;
+ };