diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2012-03-21 10:37:25 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2012-03-21 10:37:25 -0700 |
commit | 31f6765266417c0d99f0e922fe82848a7c9c2ae9 (patch) | |
tree | 2d5914dac0a918baad37decd3845b8c206051420 /Documentation/hwmon/max34440 | |
parent | d15d76448bb58c7832e954b6a8f1e301720b7866 (diff) | |
parent | 312869ec935ab3bb67b7ba641a7d11230555aff5 (diff) |
Merge tag 'hwmon-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging
Pull hwmon changes for v3.4 from Guenter Roeck:
"Mostly cleanup. No new drivers this time around, but support for
several chips added to existing drivers: TPS40400, TPS40422, MTD040,
MAX34446, ZL9101M, ZL9117M, and LM96080. Also, added watchdog support
for SCH56xx, and additional attributes for a couple of drivers."
* tag 'hwmon-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging: (137 commits)
hwmon: (sch56xx) Add support for the integrated watchdog (v2)
hwmon: (w83627ehf) Add support for temperature offset registers
hwmon: (jc42) Remove unnecessary device IDs
hwmon: (zl6100) Add support for ZL9101M and ZL9117M
hwmon: (adm1275) Add support for ADM1075
hwmon: (max34440) Add support for MAX34446
hwmon: (pmbus) Add more virtual registers
hwmon: (pmbus) Add support for Lineage Power MDT040
hwmon: (pmbus) Add support for TI TPS40400 and TPS40422
hwmon: (max34440) Add support for 'lowest' output voltage attribute
hwmon: (jc42) Convert to use devm_kzalloc
hwmon: (max16065) Convert to use devm_kzalloc
hwmon: (smm665) Convert to use devm_kzalloc
hwmon: (ltc4261) Convert to use devm_kzalloc
hwmon: (pmbus) Simplify remove functions
hwmon: (pmbus) Convert pmbus drivers to use devm_kzalloc
hwmon: (lineage-pem) Convert to use devm_kzalloc
hwmon: (hwmon-vid) Fix checkpatch issues
hwmon: (hwmon-vid) Add new entries to VRM model table
hwmon: (lm80) Add detection of NatSemi/TI LM96080
...
Diffstat (limited to 'Documentation/hwmon/max34440')
-rw-r--r-- | Documentation/hwmon/max34440 | 30 |
1 files changed, 28 insertions, 2 deletions
diff --git a/Documentation/hwmon/max34440 b/Documentation/hwmon/max34440 index 19743919ea56..04482226db20 100644 --- a/Documentation/hwmon/max34440 +++ b/Documentation/hwmon/max34440 @@ -11,6 +11,11 @@ Supported chips: Prefixes: 'max34441' Addresses scanned: - Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf + * Maxim MAX34446 + PMBus Power-Supply Data Logger + Prefixes: 'max34446' + Addresses scanned: - + Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf Author: Guenter Roeck <guenter.roeck@ericsson.com> @@ -19,8 +24,8 @@ Description ----------- This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel -Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager -and Intelligent Fan Controller. +Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager +and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger. The driver is a client driver to the core PMBus driver. Please see Documentation/hwmon/pmbus for details on PMBus client drivers. @@ -33,6 +38,13 @@ This driver does not auto-detect devices. You will have to instantiate the devices explicitly. Please see Documentation/i2c/instantiating-devices for details. +For MAX34446, the value of the currX_crit attribute determines if current or +voltage measurement is enabled for a given channel. Voltage measurement is +enabled if currX_crit is set to 0; current measurement is enabled if the +attribute is set to a positive value. Power measurement is only enabled if +channel 1 (3) is configured for voltage measurement, and channel 2 (4) is +configured for current measurement. + Platform data support --------------------- @@ -56,19 +68,31 @@ in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. +in[1-6]_lowest Historical minimum voltage. in[1-6]_highest Historical maximum voltage. in[1-6]_reset_history Write any value to reset history. + MAX34446 only supports in[1-4]. + curr[1-6]_label "iout[1-6]". curr[1-6]_input Measured current. From READ_IOUT register. curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register. curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status. curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. +curr[1-4]_average Historical average current (MAX34446 only). curr[1-6]_highest Historical maximum current. curr[1-6]_reset_history Write any value to reset history. in6 and curr6 attributes only exist for MAX34440. + MAX34446 only supports curr[1-4]. + +power[1,3]_label "pout[1,3]" +power[1,3]_input Measured power. +power[1,3]_average Historical average power. +power[1,3]_highest Historical maximum power. + + Power attributes only exist for MAX34446. temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register. temp1 is the chip's internal temperature. temp2..temp5 @@ -79,7 +103,9 @@ temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register. temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register. temp[1-8]_max_alarm Temperature high alarm. temp[1-8]_crit_alarm Temperature critical high alarm. +temp[1-8]_average Historical average temperature (MAX34446 only). temp[1-8]_highest Historical maximum temperature. temp[1-8]_reset_history Write any value to reset history. temp7 and temp8 attributes only exist for MAX34440. + MAX34446 only supports temp[1-3]. |