parent | 05a5e477687ac7a22c0791b3e899ed7d539f7b95 (diff) |
hwmon: (w83791d) Use fan divisor bits from vbat register
Update w83791d with fan bits in vbat mon register (7.48 of the
datasheet). This change allows all fans to have a divisor of 128,
and fixes a problem with incorrectly reported fan speeds.
Signed-off-by: Marc Hulsman <m.hulsman@tudelft.nl>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon/w83791d')
-rw-r--r-- | Documentation/hwmon/w83791d | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/Documentation/hwmon/w83791d b/Documentation/hwmon/w83791d index f153b2f6d62c..a67d3b7a7098 100644 --- a/Documentation/hwmon/w83791d +++ b/Documentation/hwmon/w83791d @@ -22,6 +22,7 @@ Credits: Additional contributors: Sven Anders <anders@anduras.de> + Marc Hulsman <m.hulsman@tudelft.nl> Module Parameters ----------------- @@ -67,9 +68,8 @@ on until the temperature falls below the Hysteresis value. Fan rotation speeds are reported in RPM (rotations per minute). An alarm is triggered if the rotation speed has dropped below a programmable limit. Fan -readings can be divided by a programmable divider (1, 2, 4, 8 for fan 1/2/3 -and 1, 2, 4, 8, 16, 32, 64 or 128 for fan 4/5) to give the readings more -range or accuracy. +readings can be divided by a programmable divider (1, 2, 4, 8, 16, +32, 64 or 128 for all fans) to give the readings more range or accuracy. Voltage sensors (also known as IN sensors) report their values in millivolts. An alarm is triggered if the voltage has crossed a programmable minimum |