diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2015-09-11 16:13:47 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2015-09-11 16:13:47 -0700 |
commit | 9ebd051a7d5aa7b0ce813c3c2e5b9c851e7774b9 (patch) | |
tree | 5bc54f2de4312e5fe13356779c7bf49132e2a3fd /Documentation | |
parent | 51a73ba5f409ef6f419c8ec3a0d1257633500aaa (diff) | |
parent | 5a924a07f882e866f2337bf65048be357956691a (diff) |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal updates from Zhang Rui:
- use int instead of unsigned long to represent temperature to avoid
bogus overheat detection when negative temperature reported. From
Sascha Hauer.
- export available thermal governors information to user space via
sysfs. From Wei Ni.
- introduce new thermal driver for Wildcat Point platform controller
hub, which uses PCH thermal sensor and associated critical and hot
trip points. From Tushar Dave.
- add suuport for Intel Skylake and Denlow platforms in powerclamp
driver.
- some small cleanups in thermal core.
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
thermal: Add Intel PCH thermal driver
thermal: Add comment explaining test for critical temperature
thermal: Use IS_ENABLED instead of #ifdef
thermal: remove unnecessary call to thermal_zone_device_set_polling
thermal: trivial: fix typo in comment
thermal: consistently use int for temperatures
thermal: add available policies sysfs attribute
thermal/powerclamp: add cpu id for denlow platform
thermal/powerclamp: add cpu id for Skylake u/y
thermal/powerclamp: add cpu id for skylake h/s
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 6 |
1 files changed, 6 insertions, 0 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index c1f6864a8c5d..10f062ea6bc2 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -180,6 +180,7 @@ Thermal zone device sys I/F, created once it's registered: |---temp: Current temperature |---mode: Working mode of the thermal zone |---policy: Thermal governor used for this zone + |---available_policies: Available thermal governors for this zone |---trip_point_[0-*]_temp: Trip point temperature |---trip_point_[0-*]_type: Trip point type |---trip_point_[0-*]_hyst: Hysteresis value for this trip point @@ -256,6 +257,10 @@ policy One of the various thermal governors used for a particular zone. RW, Required +available_policies + Available thermal governors which can be used for a particular zone. + RO, Required + trip_point_[0-*]_temp The temperature above which trip point will be fired. Unit: millidegree Celsius @@ -417,6 +422,7 @@ method, the sys I/F structure will be built like this: |---temp: 37000 |---mode: enabled |---policy: step_wise + |---available_policies: step_wise fair_share |---trip_point_0_temp: 100000 |---trip_point_0_type: critical |---trip_point_1_temp: 80000 |