summaryrefslogtreecommitdiff
path: root/Documentation
diff options
context:
space:
mode:
authorGong Jun <jgong@winbond.com>2007-01-18 22:14:24 +0100
committerJean Delvare <khali@arrakis.delvare>2007-01-18 22:14:24 +0100
commit46bed4dfe5f95f1fc8f68ead592a7e295bbbe01e (patch)
tree9595db3fd526ac8d3e2e54be8fd88dd3f44cf245 /Documentation
parent9fab2d8b75a4084e91f1dcb4e55368406fe53010 (diff)
hwmon/w83793: Ignore disabled temperature channels
Ignore the temperature readings when its channel is disabled, ignore AMDSI readings. Signed-off-by: Gong Jun <jgong@winbond.com> Signed-off-by: Rudolf Marek <r.marek@assembler.cz> Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/w837938
1 files changed, 2 insertions, 6 deletions
diff --git a/Documentation/hwmon/w83793 b/Documentation/hwmon/w83793
index 45e5408340e0..51171a83165b 100644
--- a/Documentation/hwmon/w83793
+++ b/Documentation/hwmon/w83793
@@ -45,18 +45,14 @@ This driver implements support for Winbond W83793G/W83793R chips.
temp5-6 have a 1 degree Celsiis resolution.
* Temperature sensor types
- Temp1-4 have 3 possible types. It can be read from (and written to)
+ Temp1-4 have 2 possible types. It can be read from (and written to)
temp[1-4]_type.
- - If the value of 0, the related temperature channel stops
- monitoring.
- If the value is 3, it starts monitoring using a remote termal diode
(default).
- - If the value is 5, it starts monitoring using the temperature sensor
- in AMD CPU and get result by AMDSI.
- If the value is 6, it starts monitoring using the temperature sensor
in Intel CPU and get result by PECI.
Temp5-6 can be connected to external thermistors (value of
- temp[5-6]_type is 4). They can also be disabled (value is 0).
+ temp[5-6]_type is 4).
* Alarm mechanism
For voltage sensors, an alarm triggers if the measured value is below