summaryrefslogtreecommitdiff
path: root/Kbuild
diff options
context:
space:
mode:
authorStefan Agner <stefan@agner.ch>2015-05-18 18:33:27 +0200
committerMax Krummenacher <max.krummenacher@toradex.com>2016-06-29 14:03:08 +0200
commit7c83cef87116c0b2aaaf867f406831643306d3d1 (patch)
tree247b1ea9cc07e97adcfc9bbf993f07852f7bb338 /Kbuild
parent4ee83828023d9fe6abbe47881d6fd3ae0e5e3c31 (diff)
If a valid power regulator or a dummy regulator is used (which happens to be the case when no regulator is specified), restart_work is queued no matter whether the device was running or not at suspend time. Since work queues get initialized in the ndo_open callback, resuming leads to a NULL pointer exception. Reverse exactly the steps executed at suspend time: - Enable the power regulator in any case - Enable the transceiver regulator if the device was running, even in case we have a power regulator - Queue restart_work only in case the device was running Fixes: bf66f3736a94 ("can: mcp251x: Move to threaded interrupts instead of workqueues.") Signed-off-by: Stefan Agner <stefan@agner.ch> Cc: linux-stable <stable@vger.kernel.org> Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de> (cherry picked from commit 25b401c1816ae64bcc5dcb1d39ab41812522a0ce) Backport conflicts: driver has been moved to spi subdir upstream drivers/net/can/spi/mcp251x.c
Diffstat (limited to 'Kbuild')
0 files changed, 0 insertions, 0 deletions