summaryrefslogtreecommitdiff
path: root/arch/arm/mach-s3c2410/Kconfig
diff options
context:
space:
mode:
authorBen Dooks <ben-linux@fluff.org>2006-12-19 23:46:17 +0100
committerRussell King <rmk+kernel@arm.linux.org.uk>2006-12-19 22:54:53 +0000
commit618b20a13e9ef4ed1d16f1ab94ccce8e4f55f9d9 (patch)
treeb8a603601694803e563bcf953e6b7b69089255d8 /arch/arm/mach-s3c2410/Kconfig
parent2d4ecdf5387a386588ae32e65f14c3c2569d9ef3 (diff)
[ARM] 4062/1: S3C24XX: Anubis and Osiris shuld have CONFIG_PM_SIMTEC
Both CONFIG_MACH_OSIRIS and CONFIG_MACH_ANUBIS should select CONFIG_PM_SIMTEC. This patch moves the selection of CONFIG_PM_SIMTEC to the machines that require it, as currently done with other machines in the S3C2410 architecture. Signed-off-by: Ben Dooks <ben-linux@fluff.org> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Diffstat (limited to 'arch/arm/mach-s3c2410/Kconfig')
-rw-r--r--arch/arm/mach-s3c2410/Kconfig10
1 files changed, 8 insertions, 2 deletions
diff --git a/arch/arm/mach-s3c2410/Kconfig b/arch/arm/mach-s3c2410/Kconfig
index 9ac6b5d1fa9b..eb4ec411312b 100644
--- a/arch/arm/mach-s3c2410/Kconfig
+++ b/arch/arm/mach-s3c2410/Kconfig
@@ -5,6 +5,7 @@ menu "S3C24XX Implementations"
config MACH_AML_M5900
bool "AML M5900 Series"
select CPU_S3C2410
+ select PM_SIMTEC if PM
help
Say Y here if you are using the American Microsystems M5900 Series
<http://www.amltd.com>
@@ -12,6 +13,7 @@ config MACH_AML_M5900
config MACH_ANUBIS
bool "Simtec Electronics ANUBIS"
select CPU_S3C2440
+ select PM_SIMTEC if PM
help
Say Y here if you are using the Simtec Electronics ANUBIS
development system
@@ -19,6 +21,7 @@ config MACH_ANUBIS
config MACH_OSIRIS
bool "Simtec IM2440D20 (OSIRIS) module"
select CPU_S3C2440
+ select PM_SIMTEC if PM
help
Say Y here if you are using the Simtec IM2440D20 module, also
known as the Osiris.
@@ -26,6 +29,7 @@ config MACH_OSIRIS
config ARCH_BAST
bool "Simtec Electronics BAST (EB2410ITX)"
select CPU_S3C2410
+ select PM_SIMTEC if PM
select ISA
help
Say Y here if you are using the Simtec Electronics EB2410ITX
@@ -111,6 +115,7 @@ config MACH_SMDK2413
config MACH_VR1000
bool "Thorcom VR1000"
+ select PM_SIMTEC if PM
select CPU_S3C2410
help
Say Y here if you are using the Thorcom VR1000 board.
@@ -297,8 +302,9 @@ config S3C2410_PM_CHECK_CHUNKSIZE
config PM_SIMTEC
bool
- depends on PM && (ARCH_BAST || MACH_VR1000 || MACH_AML_M5900)
- default y
+ help
+ Common power management code for systems that are
+ compatible with the Simtec style of power management
config S3C2410_LOWLEVEL_UART_PORT
int "S3C2410 UART to use for low-level messages"