summaryrefslogtreecommitdiff
path: root/drivers/bcma
diff options
context:
space:
mode:
authorRafał Miłecki <zajec5@gmail.com>2016-01-26 17:02:09 +0100
committerKalle Valo <kvalo@codeaurora.org>2016-02-06 13:49:17 +0200
commit515b399c9a204da70d54916d23c1748ff7083fb8 (patch)
tree0bac4fcd134da1d3c9a40c2b2e47f910420b4760 /drivers/bcma
parent61dba73cdbba8ec5c01b31beaf9e2debc2d2f273 (diff)
bcma: claim only 14e4:4365 PCI Dell card with SoftMAC BCM43142
It seems 14e4:4365 pattern is too generic as there are two devices: 1) 14e4:4365 1028:0016 with SoftMAC BCM43142 chipset 2) 14e4:4365 14e4:4365 with FullMAC BCM4366 chipset The later one was found in D-Link DIR-885L router and we want to let brcmfmac handle it. Signed-off-by: Rafał Miłecki <zajec5@gmail.com> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
Diffstat (limited to 'drivers/bcma')
-rw-r--r--drivers/bcma/host_pci.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/bcma/host_pci.c b/drivers/bcma/host_pci.c
index 0856189c065f..cae5385cf499 100644
--- a/drivers/bcma/host_pci.c
+++ b/drivers/bcma/host_pci.c
@@ -294,7 +294,7 @@ static const struct pci_device_id bcma_pci_bridge_tbl[] = {
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x4358) },
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x4359) },
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x4360) },
- { PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x4365) },
+ { PCI_DEVICE_SUB(PCI_VENDOR_ID_BROADCOM, 0x4365, PCI_VENDOR_ID_DELL, 0x0016) },
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x43a0) },
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x43a9) },
{ PCI_DEVICE(PCI_VENDOR_ID_BROADCOM, 0x43aa) },