diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2011-04-07 11:14:49 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2011-04-07 11:14:49 -0700 |
commit | 42933bac11e811f02200c944d8562a15f8ec4ff0 (patch) | |
tree | fcdd9afe56eb0e746565ddd1f92f22d36678b843 /drivers/net/bnx2x/bnx2x_link.c | |
parent | 2b9accbee563f535046ff2cd382d0acaa92e130c (diff) | |
parent | 25985edcedea6396277003854657b5f3cb31a628 (diff) |
Merge branch 'for-linus2' of git://git.profusion.mobi/users/lucas/linux-2.6
* 'for-linus2' of git://git.profusion.mobi/users/lucas/linux-2.6:
Fix common misspellings
Diffstat (limited to 'drivers/net/bnx2x/bnx2x_link.c')
-rw-r--r-- | drivers/net/bnx2x/bnx2x_link.c | 14 |
1 files changed, 7 insertions, 7 deletions
diff --git a/drivers/net/bnx2x/bnx2x_link.c b/drivers/net/bnx2x/bnx2x_link.c index f2f367d4e74d..974ef2be36a5 100644 --- a/drivers/net/bnx2x/bnx2x_link.c +++ b/drivers/net/bnx2x/bnx2x_link.c @@ -2823,7 +2823,7 @@ static u16 bnx2x_wait_reset_complete(struct bnx2x *bp, struct link_params *params) { u16 cnt, ctrl; - /* Wait for soft reset to get cleared upto 1 sec */ + /* Wait for soft reset to get cleared up to 1 sec */ for (cnt = 0; cnt < 1000; cnt++) { bnx2x_cl45_read(bp, phy, MDIO_PMA_DEVAD, MDIO_PMA_REG_CTRL, &ctrl); @@ -4141,7 +4141,7 @@ static u8 bnx2x_8073_config_init(struct bnx2x_phy *phy, val = (1<<5); /* * Note that 2.5G works only when used with 1G - * advertisment + * advertisement */ } else val = (1<<5); @@ -4151,7 +4151,7 @@ static u8 bnx2x_8073_config_init(struct bnx2x_phy *phy, PORT_HW_CFG_SPEED_CAPABILITY_D0_10G) val |= (1<<7); - /* Note that 2.5G works only when used with 1G advertisment */ + /* Note that 2.5G works only when used with 1G advertisement */ if (phy->speed_cap_mask & (PORT_HW_CFG_SPEED_CAPABILITY_D0_1G | PORT_HW_CFG_SPEED_CAPABILITY_D0_2_5G)) @@ -5232,14 +5232,14 @@ static u8 bnx2x_8706_config_init(struct bnx2x_phy *phy, bnx2x_cl45_write(bp, phy, MDIO_PMA_DEVAD, MDIO_PMA_REG_LASI_CTRL, 1); } else { - /* Force 1Gbps using autoneg with 1G advertisment */ + /* Force 1Gbps using autoneg with 1G advertisement */ /* Allow CL37 through CL73 */ DP(NETIF_MSG_LINK, "XGXS 8706 AutoNeg\n"); bnx2x_cl45_write(bp, phy, MDIO_AN_DEVAD, MDIO_AN_REG_CL37_CL73, 0x040c); - /* Enable Full-Duplex advertisment on CL37 */ + /* Enable Full-Duplex advertisement on CL37 */ bnx2x_cl45_write(bp, phy, MDIO_AN_DEVAD, MDIO_AN_REG_CL37_FC_LP, 0x0020); /* Enable CL37 AN */ @@ -6269,7 +6269,7 @@ static u8 bnx2x_848x3_config_init(struct bnx2x_phy *phy, switch (actual_phy_selection) { case PORT_HW_CFG_PHY_SELECTION_HARDWARE_DEFAULT: - /* Do nothing. Essentialy this is like the priority copper */ + /* Do nothing. Essentially this is like the priority copper */ break; case PORT_HW_CFG_PHY_SELECTION_FIRST_PHY_PRIORITY: val |= MDIO_CTL_REG_84823_MEDIA_PRIORITY_COPPER; @@ -7765,7 +7765,7 @@ u8 bnx2x_link_reset(struct link_params *params, struct link_vars *vars, REG_WR(bp, NIG_REG_NIG_EMAC0_EN + port*4, 0); msleep(10); - /* The PHY reset is controled by GPIO 1 + /* The PHY reset is controlled by GPIO 1 * Hold it as vars low */ /* clear link led */ |