summaryrefslogtreecommitdiff
path: root/drivers/power
diff options
context:
space:
mode:
authorHans de Goede <hdegoede@redhat.com>2022-02-12 17:48:16 +0100
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2022-04-15 14:18:14 +0200
commite2cd206815a68c159f32a545be94013018c0131b (patch)
treed4bb80d804d3f323e63605c37f1747f32e27adb6 /drivers/power
parenta725070701883fe62266ee6d2f31d67e6cdd31df (diff)
power: supply: bq24190_charger: Fix bq24190_vbus_is_enabled() wrong false return
[ Upstream commit f7731754fdce33dad19be746f647d6ac47c5d695 ] The datasheet says that the BQ24190_REG_POC_CHG_CONFIG bits can have a value of either 10(0x2) or 11(0x3) for OTG (5V boost regulator) mode. Sofar bq24190_vbus_is_enabled() was only checking for 10 but some BIOS-es uses 11 when enabling the regulator at boot. Make bq24190_vbus_is_enabled() also check for 11 so that it does not wrongly returns false when the bits are set to 11. Fixes: 66b6bef2c4e0 ("power: supply: bq24190_charger: Export 5V boost converter as regulator") Cc: Bastien Nocera <hadess@hadess.net> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/bq24190_charger.c7
1 files changed, 6 insertions, 1 deletions
diff --git a/drivers/power/supply/bq24190_charger.c b/drivers/power/supply/bq24190_charger.c
index 1ae5d6d42c9e..64d87dccea82 100644
--- a/drivers/power/supply/bq24190_charger.c
+++ b/drivers/power/supply/bq24190_charger.c
@@ -41,6 +41,7 @@
#define BQ24190_REG_POC_CHG_CONFIG_DISABLE 0x0
#define BQ24190_REG_POC_CHG_CONFIG_CHARGE 0x1
#define BQ24190_REG_POC_CHG_CONFIG_OTG 0x2
+#define BQ24190_REG_POC_CHG_CONFIG_OTG_ALT 0x3
#define BQ24190_REG_POC_SYS_MIN_MASK (BIT(3) | BIT(2) | BIT(1))
#define BQ24190_REG_POC_SYS_MIN_SHIFT 1
#define BQ24190_REG_POC_SYS_MIN_MIN 3000
@@ -550,7 +551,11 @@ static int bq24190_vbus_is_enabled(struct regulator_dev *dev)
pm_runtime_mark_last_busy(bdi->dev);
pm_runtime_put_autosuspend(bdi->dev);
- return ret ? ret : val == BQ24190_REG_POC_CHG_CONFIG_OTG;
+ if (ret)
+ return ret;
+
+ return (val == BQ24190_REG_POC_CHG_CONFIG_OTG ||
+ val == BQ24190_REG_POC_CHG_CONFIG_OTG_ALT);
}
static const struct regulator_ops bq24190_vbus_ops = {