diff options
author | Vasu Dev <vasu.dev@intel.com> | 2012-03-09 14:49:58 -0800 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2012-03-28 09:04:51 +0100 |
commit | 73d67aa40b1f94a4e5edecbbc3b94d352eeeae0a (patch) | |
tree | 95a72d5091271f7cb40580990b34db98ca603019 /drivers/scsi/libfc | |
parent | 14619ea689cc0b257cf998469005d0515133d7bc (diff) |
[SCSI] libfc: update fc_host mfs along with updating lport->mfs
Currently fc_host mfs is not getting updated in
case its changed during FLOGI and that leaves fc_host
to show its initial old value in sysfs, so instead
have fc_host mfs updated along with updating lport mfs
during FLOGI.
Also in case of bad mfs during flogi, error out
instead of continuing with flogi.
[ Changes made by Robert Love: condition to '>=' and
added printing of lport->mfs in DBG statement. FLOGI
resp processing failed without being able to compare
FCoE MFS 2112 against an incoming MFS of 2112 ]
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi/libfc')
-rw-r--r-- | drivers/scsi/libfc/fc_lport.c | 10 |
1 files changed, 9 insertions, 1 deletions
diff --git a/drivers/scsi/libfc/fc_lport.c b/drivers/scsi/libfc/fc_lport.c index 9a0b2a9caad6..4f7ef76aa795 100644 --- a/drivers/scsi/libfc/fc_lport.c +++ b/drivers/scsi/libfc/fc_lport.c @@ -1743,8 +1743,16 @@ void fc_lport_flogi_resp(struct fc_seq *sp, struct fc_frame *fp, mfs = ntohs(flp->fl_csp.sp_bb_data) & FC_SP_BB_DATA_MASK; if (mfs >= FC_SP_MIN_MAX_PAYLOAD && - mfs < lport->mfs) + mfs <= lport->mfs) { lport->mfs = mfs; + fc_host_maxframe_size(lport->host) = mfs; + } else { + FC_LPORT_DBG(lport, "FLOGI bad mfs:%hu response, " + "lport->mfs:%hu\n", mfs, lport->mfs); + fc_lport_error(lport, fp); + goto err; + } + csp_flags = ntohs(flp->fl_csp.sp_features); r_a_tov = ntohl(flp->fl_csp.sp_r_a_tov); e_d_tov = ntohl(flp->fl_csp.sp_e_d_tov); |