diff options
author | Don Brace <don.brace@pmcs.com> | 2015-01-23 16:45:07 -0600 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2015-02-02 09:57:44 -0800 |
commit | 27fb8137299d4b0ee1d248d369e8c7a1dccf54dc (patch) | |
tree | d1a429a929356c6da7154de3d1776e8c8eb25c21 /drivers/scsi | |
parent | c706a7954a160ddc1a29e1dfe4dc1f58e2b95023 (diff) |
hpsa: add in gen9 controller model names
Add in gen9 controller model names
Reviewed-by: Scott Teel <scott.teel@pmcs.com>
Signed-off-by: Don Brace <don.brace@pmcs.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Diffstat (limited to 'drivers/scsi')
-rw-r--r-- | drivers/scsi/hpsa.c | 26 |
1 files changed, 13 insertions, 13 deletions
diff --git a/drivers/scsi/hpsa.c b/drivers/scsi/hpsa.c index c1f4a95d5d5d..6568da5d7915 100644 --- a/drivers/scsi/hpsa.c +++ b/drivers/scsi/hpsa.c @@ -168,24 +168,24 @@ static struct board_type products[] = { {0x1926103C, "Smart Array P731m", &SA5_access}, {0x1928103C, "Smart Array P230i", &SA5_access}, {0x1929103C, "Smart Array P530", &SA5_access}, - {0x21BD103C, "Smart Array", &SA5_access}, - {0x21BE103C, "Smart Array", &SA5_access}, - {0x21BF103C, "Smart Array", &SA5_access}, - {0x21C0103C, "Smart Array", &SA5_access}, + {0x21BD103C, "Smart Array P244br", &SA5_access}, + {0x21BE103C, "Smart Array P741m", &SA5_access}, + {0x21BF103C, "Smart HBA H240ar", &SA5_access}, + {0x21C0103C, "Smart Array P440ar", &SA5_access}, {0x21C1103C, "Smart Array", &SA5_access}, - {0x21C2103C, "Smart Array", &SA5_access}, - {0x21C3103C, "Smart Array", &SA5_access}, + {0x21C2103C, "Smart Array P440", &SA5_access}, + {0x21C3103C, "Smart Array P441", &SA5_access}, {0x21C4103C, "Smart Array", &SA5_access}, - {0x21C5103C, "Smart Array", &SA5_access}, - {0x21C6103C, "Smart Array", &SA5_access}, - {0x21C7103C, "Smart Array", &SA5_access}, - {0x21C8103C, "Smart Array", &SA5_access}, + {0x21C5103C, "Smart Array P841", &SA5_access}, + {0x21C6103C, "Smart HBA H244br", &SA5_access}, + {0x21C7103C, "Smart HBA H240", &SA5_access}, + {0x21C8103C, "Smart HBA H241", &SA5_access}, {0x21C9103C, "Smart Array", &SA5_access}, - {0x21CA103C, "Smart Array", &SA5_access}, - {0x21CB103C, "Smart Array", &SA5_access}, + {0x21CA103C, "Smart Array P246br", &SA5_access}, + {0x21CB103C, "Smart Array P840", &SA5_access}, {0x21CC103C, "Smart Array", &SA5_access}, {0x21CD103C, "Smart Array", &SA5_access}, - {0x21CE103C, "Smart Array", &SA5_access}, + {0x21CE103C, "Smart HBA", &SA5_access}, {0x00761590, "HP Storage P1224 Array Controller", &SA5_access}, {0x00871590, "HP Storage P1224e Array Controller", &SA5_access}, {0x007D1590, "HP Storage P1228 Array Controller", &SA5_access}, |