diff options
author | nagalakshmi.nandigama@lsi.com <nagalakshmi.nandigama@lsi.com> | 2011-12-01 07:52:42 +0530 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2011-12-15 10:57:33 +0400 |
commit | 8bad3055e902a16b7cf47777fc3e78a965d0b57a (patch) | |
tree | 09f3217e551df0480a1c213f065304fca1aff06e /drivers/scsi | |
parent | 9ac49d3a510c2686545d4e0520fdc79b341b5794 (diff) |
[SCSI] mpt2sas: Added support for customer specific branding
Signed-off-by: Nagalakshmi Nandigama <nagalakshmi.nandigama@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi')
-rw-r--r-- | drivers/scsi/mpt2sas/mpt2sas_base.c | 16 | ||||
-rw-r--r-- | drivers/scsi/mpt2sas/mpt2sas_base.h | 12 |
2 files changed, 28 insertions, 0 deletions
diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.c b/drivers/scsi/mpt2sas/mpt2sas_base.c index 4a8706867700..c0526878a337 100644 --- a/drivers/scsi/mpt2sas/mpt2sas_base.c +++ b/drivers/scsi/mpt2sas/mpt2sas_base.c @@ -1988,6 +1988,22 @@ _base_display_intel_branding(struct MPT2SAS_ADAPTER *ioc) printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, MPT2SAS_INTEL_RS25GB008_BRANDING); break; + case MPT2SAS_INTEL_RMS25JB080_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25JB080_BRANDING); + break; + case MPT2SAS_INTEL_RMS25JB040_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25JB040_BRANDING); + break; + case MPT2SAS_INTEL_RMS25KB080_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25KB080_BRANDING); + break; + case MPT2SAS_INTEL_RMS25KB040_SSDID: + printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, + MPT2SAS_INTEL_RMS25KB040_BRANDING); + break; default: break; } diff --git a/drivers/scsi/mpt2sas/mpt2sas_base.h b/drivers/scsi/mpt2sas/mpt2sas_base.h index 88ead5ed2afc..f2b7e40f105c 100644 --- a/drivers/scsi/mpt2sas/mpt2sas_base.h +++ b/drivers/scsi/mpt2sas/mpt2sas_base.h @@ -157,6 +157,14 @@ /* * Intel HBA branding */ +#define MPT2SAS_INTEL_RMS25JB080_BRANDING \ + "Intel(R) Integrated RAID Module RMS25JB080" +#define MPT2SAS_INTEL_RMS25JB040_BRANDING \ + "Intel(R) Integrated RAID Module RMS25JB040" +#define MPT2SAS_INTEL_RMS25KB080_BRANDING \ + "Intel(R) Integrated RAID Module RMS25KB080" +#define MPT2SAS_INTEL_RMS25KB040_BRANDING \ + "Intel(R) Integrated RAID Module RMS25KB040" #define MPT2SAS_INTEL_RMS2LL080_BRANDING \ "Intel Integrated RAID Module RMS2LL080" #define MPT2SAS_INTEL_RMS2LL040_BRANDING \ @@ -168,6 +176,10 @@ /* * Intel HBA SSDIDs */ +#define MPT2SAS_INTEL_RMS25JB080_SSDID 0x3516 +#define MPT2SAS_INTEL_RMS25JB040_SSDID 0x3517 +#define MPT2SAS_INTEL_RMS25KB080_SSDID 0x3518 +#define MPT2SAS_INTEL_RMS25KB040_SSDID 0x3519 #define MPT2SAS_INTEL_RMS2LL080_SSDID 0x350E #define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F #define MPT2SAS_INTEL_RS25GB008_SSDID 0x3000 |