diff options
author | Jan Kiszka <jan.kiszka@siemens.com> | 2018-08-26 19:49:32 +0200 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2018-10-10 08:54:18 +0200 |
commit | cdb2d37d345d694fcf83291c1a5b5465f743fd73 (patch) | |
tree | efd7c123c725b6c96cd57cc2f14951b5406a2988 /drivers/tty/serial/mvebu-uart.c | |
parent | a17e2a72e714ca20c31e41827ab6088df896c190 (diff) |
serial: mvebu-uart: Fix reporting of effective CSIZE to userspace
commit e0bf2d4982fe7d9ddaf550dd023803ea286f47fc upstream.
Apparently, this driver (or the hardware) does not support character
length settings. It's apparently running in 8-bit mode, but it makes
userspace believe it's in 5-bit mode. That makes tcsetattr with CS8
incorrectly fail, breaking e.g. getty from busybox, thus the login shell
on ttyMVx.
Fix by hard-wiring CS8 into c_cflag.
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Fixes: 30530791a7a0 ("serial: mvebu-uart: initial support for Armada-3700 serial port")
Cc: stable <stable@vger.kernel.org> # 4.6+
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers/tty/serial/mvebu-uart.c')
-rw-r--r-- | drivers/tty/serial/mvebu-uart.c | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/drivers/tty/serial/mvebu-uart.c b/drivers/tty/serial/mvebu-uart.c index 45b57c294d13..401c983ec5f3 100644 --- a/drivers/tty/serial/mvebu-uart.c +++ b/drivers/tty/serial/mvebu-uart.c @@ -327,8 +327,10 @@ static void mvebu_uart_set_termios(struct uart_port *port, if ((termios->c_cflag & CREAD) == 0) port->ignore_status_mask |= STAT_RX_RDY | STAT_BRK_ERR; - if (old) + if (old) { tty_termios_copy_hw(termios, old); + termios->c_cflag |= CS8; + } baud = uart_get_baud_rate(port, termios, old, 0, 460800); uart_update_timeout(port, termios->c_cflag, baud); |