summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
authorDavid Woodhouse <David.Woodhouse@intel.com>2008-08-02 00:01:21 +0100
committerDavid Woodhouse <David.Woodhouse@intel.com>2008-08-02 07:52:39 +0100
commitf1136d022af8f07a97f59c6d07483bdb82ffbd8e (patch)
tree459531ff8179263f50494ab040070ea609ebb5ff /drivers
parent759da9267177e5005c8f21e11d29d26f4f459744 (diff)
[MTD] Fix !CONFIG_BLOCK compile for mtdsuper.c
As reported by Adrian Bunk, commit d5686b444ff3f72808d2b3fbd58672a86cdf38e7 (switch mtd and dm-table to lookup_bdev()) causes the following compile error with CONFIG_BLOCK=n: CC drivers/mtd/mtdsuper.o drivers/mtd/mtdsuper.c: In function `get_sb_mtd': drivers/mtd/mtdsuper.c:184: error: implicit declaration of function 'lookup_bdev' drivers/mtd/mtdsuper.c:184: warning: assignment makes pointer from integer without a cast drivers/mtd/mtdsuper.c:197: error: implicit declaration of function 'bdput' make[3]: *** [drivers/mtd/mtdsuper.o] Error 1 Fix it by putting the block device lookup inside #ifdef CONFIG_BLOCK Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/mtd/mtdsuper.c17
1 files changed, 12 insertions, 5 deletions
diff --git a/drivers/mtd/mtdsuper.c b/drivers/mtd/mtdsuper.c
index 9b6af7e74a65..00d46e137b2a 100644
--- a/drivers/mtd/mtdsuper.c
+++ b/drivers/mtd/mtdsuper.c
@@ -125,8 +125,11 @@ int get_sb_mtd(struct file_system_type *fs_type, int flags,
int (*fill_super)(struct super_block *, void *, int),
struct vfsmount *mnt)
{
+#ifdef CONFIG_BLOCK
struct block_device *bdev;
- int mtdnr, ret;
+ int ret, major;
+#endif
+ int mtdnr;
if (!dev_name)
return -EINVAL;
@@ -178,6 +181,7 @@ int get_sb_mtd(struct file_system_type *fs_type, int flags,
}
}
+#ifdef CONFIG_BLOCK
/* try the old way - the hack where we allowed users to mount
* /dev/mtdblock$(n) but didn't actually _use_ the blockdev
*/
@@ -190,22 +194,25 @@ int get_sb_mtd(struct file_system_type *fs_type, int flags,
DEBUG(1, "MTDSB: lookup_bdev() returned 0\n");
ret = -EINVAL;
- if (MAJOR(bdev->bd_dev) != MTD_BLOCK_MAJOR)
- goto not_an_MTD_device;
+ major = MAJOR(bdev->bd_dev);
mtdnr = MINOR(bdev->bd_dev);
bdput(bdev);
+ if (major != MTD_BLOCK_MAJOR)
+ goto not_an_MTD_device;
+
return get_sb_mtd_nr(fs_type, flags, dev_name, data, mtdnr, fill_super,
mnt);
not_an_MTD_device:
+#endif /* CONFIG_BLOCK */
+
if (!(flags & MS_SILENT))
printk(KERN_NOTICE
"MTD: Attempt to mount non-MTD device \"%s\"\n",
dev_name);
- bdput(bdev);
- return ret;
+ return -EINVAL;
}
EXPORT_SYMBOL_GPL(get_sb_mtd);