diff options
author | Maksim Salau <msalau@iotecha.com> | 2017-10-11 11:10:52 +0300 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2017-10-27 10:38:05 +0200 |
commit | b7cd9f5664e1dbb6a077c8a69e3bb5aed7c9285e (patch) | |
tree | 8e756a59a67bce77007ba6536928bf737ebcbdb9 /drivers | |
parent | 603296156ba47b1f4a3e18937e79755c57f1da50 (diff) |
usb: cdc_acm: Add quirk for Elatec TWN3
commit 765fb2f181cad669f2beb87842a05d8071f2be85 upstream.
Elatec TWN3 has the union descriptor on data interface. This results in
failure to bind the device to the driver with the following log:
usb 1-1.2: new full speed USB device using streamplug-ehci and address 4
usb 1-1.2: New USB device found, idVendor=09d8, idProduct=0320
usb 1-1.2: New USB device strings: Mfr=1, Product=2, SerialNumber=0
usb 1-1.2: Product: RFID Device (COM)
usb 1-1.2: Manufacturer: OEM
cdc_acm 1-1.2:1.0: Zero length descriptor references
cdc_acm: probe of 1-1.2:1.0 failed with error -22
Adding the NO_UNION_NORMAL quirk for the device fixes the issue.
`lsusb -v` of the device:
Bus 001 Device 003: ID 09d8:0320
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 2 Communications
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 32
idVendor 0x09d8
idProduct 0x0320
bcdDevice 3.00
iManufacturer 1 OEM
iProduct 2 RFID Device (COM)
iSerial 0
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 67
bNumInterfaces 2
bConfigurationValue 1
iConfiguration 0
bmAttributes 0x80
(Bus Powered)
MaxPower 250mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 1
bInterfaceClass 2 Communications
bInterfaceSubClass 2 Abstract (modem)
bInterfaceProtocol 1 AT-commands (v.25ter)
iInterface 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x83 EP 3 IN
bmAttributes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0020 1x 32 bytes
bInterval 2
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 1
bAlternateSetting 0
bNumEndpoints 2
bInterfaceClass 10 CDC Data
bInterfaceSubClass 0 Unused
bInterfaceProtocol 0
iInterface 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x02 EP 2 OUT
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0020 1x 32 bytes
bInterval 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 EP 1 IN
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0020 1x 32 bytes
bInterval 0
CDC Header:
bcdCDC 1.10
CDC Call Management:
bmCapabilities 0x03
call management
use DataInterface
bDataInterface 1
CDC ACM:
bmCapabilities 0x06
sends break
line coding and serial state
CDC Union:
bMasterInterface 0
bSlaveInterface 1
Device Status: 0x0000
(Bus Powered)
Signed-off-by: Maksim Salau <msalau@iotecha.com>
Acked-by: Oliver Neukum <oneukum@suse.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/usb/class/cdc-acm.c | 3 |
1 files changed, 3 insertions, 0 deletions
diff --git a/drivers/usb/class/cdc-acm.c b/drivers/usb/class/cdc-acm.c index f16491c25e73..ea20b2cc189f 100644 --- a/drivers/usb/class/cdc-acm.c +++ b/drivers/usb/class/cdc-acm.c @@ -1773,6 +1773,9 @@ static const struct usb_device_id acm_ids[] = { { USB_DEVICE(0xfff0, 0x0100), /* DATECS FP-2000 */ .driver_info = NO_UNION_NORMAL, /* reports zero length descriptor */ }, + { USB_DEVICE(0x09d8, 0x0320), /* Elatec GmbH TWN3 */ + .driver_info = NO_UNION_NORMAL, /* has misplaced union descriptor */ + }, { USB_DEVICE(0x2912, 0x0001), /* ATOL FPrint */ .driver_info = CLEAR_HALT_CONDITIONS, |