diff options
author | Cong Wang <xiyou.wangcong@gmail.com> | 2012-05-15 14:57:33 +0800 |
---|---|---|
committer | Al Viro <viro@zeniv.linux.org.uk> | 2012-05-30 21:04:52 -0400 |
commit | 3ed37648e1cbf1bbebc200c6ea8fd8daf8325843 (patch) | |
tree | 60f27fc77a1e5c9c48790243266367318a3267dc /fs/inode.c | |
parent | 8bdc81c5069e43755d6e59e5e990e21ca200e8e2 (diff) |
fs: move file_remove_suid() to fs/inode.c
file_remove_suid() is a generic function operates on struct file,
it almost has no relations with file mapping, so move it to fs/inode.c.
Cc: Alexander Viro <viro@zeniv.linux.org.uk>
Signed-off-by: Cong Wang <xiyou.wangcong@gmail.com>
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Diffstat (limited to 'fs/inode.c')
-rw-r--r-- | fs/inode.c | 65 |
1 files changed, 65 insertions, 0 deletions
diff --git a/fs/inode.c b/fs/inode.c index 183ddd6cda71..a79555e492e0 100644 --- a/fs/inode.c +++ b/fs/inode.c @@ -1530,6 +1530,71 @@ void touch_atime(struct path *path) } EXPORT_SYMBOL(touch_atime); +/* + * The logic we want is + * + * if suid or (sgid and xgrp) + * remove privs + */ +int should_remove_suid(struct dentry *dentry) +{ + umode_t mode = dentry->d_inode->i_mode; + int kill = 0; + + /* suid always must be killed */ + if (unlikely(mode & S_ISUID)) + kill = ATTR_KILL_SUID; + + /* + * sgid without any exec bits is just a mandatory locking mark; leave + * it alone. If some exec bits are set, it's a real sgid; kill it. + */ + if (unlikely((mode & S_ISGID) && (mode & S_IXGRP))) + kill |= ATTR_KILL_SGID; + + if (unlikely(kill && !capable(CAP_FSETID) && S_ISREG(mode))) + return kill; + + return 0; +} +EXPORT_SYMBOL(should_remove_suid); + +static int __remove_suid(struct dentry *dentry, int kill) +{ + struct iattr newattrs; + + newattrs.ia_valid = ATTR_FORCE | kill; + return notify_change(dentry, &newattrs); +} + +int file_remove_suid(struct file *file) +{ + struct dentry *dentry = file->f_path.dentry; + struct inode *inode = dentry->d_inode; + int killsuid; + int killpriv; + int error = 0; + + /* Fast path for nothing security related */ + if (IS_NOSEC(inode)) + return 0; + + killsuid = should_remove_suid(dentry); + killpriv = security_inode_need_killpriv(dentry); + + if (killpriv < 0) + return killpriv; + if (killpriv) + error = security_inode_killpriv(dentry); + if (!error && killsuid) + error = __remove_suid(dentry, killsuid); + if (!error && (inode->i_sb->s_flags & MS_NOSEC)) + inode->i_flags |= S_NOSEC; + + return error; +} +EXPORT_SYMBOL(file_remove_suid); + /** * file_update_time - update mtime and ctime time * @file: file accessed |