summaryrefslogtreecommitdiff
path: root/include/linux/mfd/abx500.h
diff options
context:
space:
mode:
authorMarcus Cooper <marcus.xm.cooper@stericsson.com>2013-01-11 13:12:54 +0000
committerAnton Vorontsov <anton@enomsg.org>2013-01-15 17:43:46 -0800
commitea4024017831d61874351defe8f8c58ae73f8009 (patch)
tree0411f756d15ee826c05a603e1218125a0410fcc0 /include/linux/mfd/abx500.h
parenta864c5a869dcdb40617fc15166385e0ffa609592 (diff)
ab8500_bm: Recharge condition not optimal for battery
Today the battery recharge is determined with a voltage threshold. This voltage threshold is only valid when the battery is relaxed. In charging algorithm the voltage read is the loaded battery voltage and no compensation is done to get the relaxed voltage. When maintenance charging is not selected, this makes the recharging condition to almost immediately activate when there is a discharge present on the battery. Depending on which vendor the battery comes from this behavior can wear out the battery much faster than normal. The fuelgauge driver is responsible to monitor the actual battery capacity and is able to estimate the remaining capacity. It is better to use the remaining capacity as a limit to determine when battery should be recharged. Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com> Reviewed-by: Hakan BERG <hakan.berg@stericsson.com> Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com> Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Diffstat (limited to 'include/linux/mfd/abx500.h')
-rw-r--r--include/linux/mfd/abx500.h6
1 files changed, 4 insertions, 2 deletions
diff --git a/include/linux/mfd/abx500.h b/include/linux/mfd/abx500.h
index 4906b1842d2f..0e6e90badfca 100644
--- a/include/linux/mfd/abx500.h
+++ b/include/linux/mfd/abx500.h
@@ -131,7 +131,7 @@ struct abx500_maxim_parameters {
* @nominal_voltage: Nominal voltage of the battery in mV
* @termination_vol: max voltage upto which battery can be charged
* @termination_curr battery charging termination current in mA
- * @recharge_vol battery voltage limit that will trigger a new
+ * @recharge_cap battery capacity limit that will trigger a new
* full charging cycle in the case where maintenan-
* -ce charging has been disabled
* @normal_cur_lvl: charger current in normal state in mA
@@ -160,7 +160,7 @@ struct abx500_battery_type {
int nominal_voltage;
int termination_vol;
int termination_curr;
- int recharge_vol;
+ int recharge_cap;
int normal_cur_lvl;
int normal_vol_lvl;
int maint_a_cur_lvl;
@@ -224,6 +224,7 @@ struct abx500_bm_charger_parameters {
* @bkup_bat_v voltage which we charge the backup battery with
* @bkup_bat_i current which we charge the backup battery with
* @no_maintenance indicates that maintenance charging is disabled
+ * @capacity_scaling indicates whether capacity scaling is to be used
* @abx500_adc_therm placement of thermistor, batctrl or battemp adc
* @chg_unknown_bat flag to enable charging of unknown batteries
* @enable_overshoot flag to enable VBAT overshoot control
@@ -254,6 +255,7 @@ struct abx500_bm_data {
int bkup_bat_v;
int bkup_bat_i;
bool no_maintenance;
+ bool capacity_scaling;
bool chg_unknown_bat;
bool enable_overshoot;
bool auto_trig;