summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--drivers/cpufreq/cpufreq-dt.c51
1 files changed, 32 insertions, 19 deletions
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index 7374fc4b6bb3..e720954244b1 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -186,7 +186,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
{
struct cpufreq_dt_platform_data *pd;
struct cpufreq_frequency_table *freq_table;
- struct thermal_cooling_device *cdev;
struct device_node *np;
struct private_data *priv;
struct device *cpu_dev;
@@ -269,20 +268,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
goto out_free_priv;
}
- /*
- * For now, just loading the cooling device;
- * thermal DT code takes care of matching them.
- */
- if (of_find_property(np, "#cooling-cells", NULL)) {
- cdev = of_cpufreq_cooling_register(np, policy->related_cpus);
- if (IS_ERR(cdev))
- dev_err(cpu_dev,
- "running cpufreq without cooling device: %ld\n",
- PTR_ERR(cdev));
- else
- priv->cdev = cdev;
- }
-
priv->cpu_dev = cpu_dev;
priv->cpu_reg = cpu_reg;
policy->driver_data = priv;
@@ -292,7 +277,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
if (ret) {
dev_err(cpu_dev, "%s: invalid frequency table: %d\n", __func__,
ret);
- goto out_cooling_unregister;
+ goto out_free_cpufreq_table;
}
policy->cpuinfo.transition_latency = transition_latency;
@@ -305,8 +290,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
return 0;
-out_cooling_unregister:
- cpufreq_cooling_unregister(priv->cdev);
+out_free_cpufreq_table:
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
out_free_priv:
kfree(priv);
@@ -324,7 +308,8 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
- cpufreq_cooling_unregister(priv->cdev);
+ if (priv->cdev)
+ cpufreq_cooling_unregister(priv->cdev);
dev_pm_opp_free_cpufreq_table(priv->cpu_dev, &policy->freq_table);
clk_put(policy->clk);
if (!IS_ERR(priv->cpu_reg))
@@ -334,6 +319,33 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
return 0;
}
+static void cpufreq_ready(struct cpufreq_policy *policy)
+{
+ struct private_data *priv = policy->driver_data;
+ struct device_node *np = of_node_get(priv->cpu_dev->of_node);
+
+ if (WARN_ON(!np))
+ return;
+
+ /*
+ * For now, just loading the cooling device;
+ * thermal DT code takes care of matching them.
+ */
+ if (of_find_property(np, "#cooling-cells", NULL)) {
+ priv->cdev = of_cpufreq_cooling_register(np,
+ policy->related_cpus);
+ if (IS_ERR(priv->cdev)) {
+ dev_err(priv->cpu_dev,
+ "running cpufreq without cooling device: %ld\n",
+ PTR_ERR(priv->cdev));
+
+ priv->cdev = NULL;
+ }
+ }
+
+ of_node_put(np);
+}
+
static struct cpufreq_driver dt_cpufreq_driver = {
.flags = CPUFREQ_STICKY | CPUFREQ_NEED_INITIAL_FREQ_CHECK,
.verify = cpufreq_generic_frequency_table_verify,
@@ -341,6 +353,7 @@ static struct cpufreq_driver dt_cpufreq_driver = {
.get = cpufreq_generic_get,
.init = cpufreq_init,
.exit = cpufreq_exit,
+ .ready = cpufreq_ready,
.name = "cpufreq-dt",
.attr = cpufreq_generic_attr,
};