diff options
-rw-r--r-- | Documentation/ABI/stable/sysfs-class-infiniband | 818 | ||||
-rw-r--r-- | Documentation/ABI/testing/sysfs-class-infiniband | 16 | ||||
-rw-r--r-- | Documentation/infiniband/sysfs.txt | 129 |
3 files changed, 820 insertions, 143 deletions
diff --git a/Documentation/ABI/stable/sysfs-class-infiniband b/Documentation/ABI/stable/sysfs-class-infiniband new file mode 100644 index 000000000000..17211ceb9bf4 --- /dev/null +++ b/Documentation/ABI/stable/sysfs-class-infiniband @@ -0,0 +1,818 @@ +sysfs interface common for all infiniband devices +------------------------------------------------- + +What: /sys/class/infiniband/<device>/node_type +What: /sys/class/infiniband/<device>/node_guid +What: /sys/class/infiniband/<device>/sys_image_guid +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + node_type: (RO) Node type (CA, RNIC, usNIC, usNIC UDP, + switch or router) + + node_guid: (RO) Node GUID + + sys_image_guid: (RO) System image GUID + + +What: /sys/class/infiniband/<device>/node_desc +Date: Feb, 2006 +KernelVersion: v2.6.17 +Contact: linux-rdma@vger.kernel.org +Description: + (RW) Update the node description with information such as the + node's hostname, so that IB network management software can tie + its view to the real world. + + +What: /sys/class/infiniband/<device>/fw_ver +Date: Jun, 2016 +KernelVersion: v4.10 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Display firmware version + + +What: /sys/class/infiniband/<device>/ports/<port-num>/lid +What: /sys/class/infiniband/<device>/ports/<port-num>/rate +What: /sys/class/infiniband/<device>/ports/<port-num>/lid_mask_count +What: /sys/class/infiniband/<device>/ports/<port-num>/sm_sl +What: /sys/class/infiniband/<device>/ports/<port-num>/sm_lid +What: /sys/class/infiniband/<device>/ports/<port-num>/state +What: /sys/class/infiniband/<device>/ports/<port-num>/phys_state +What: /sys/class/infiniband/<device>/ports/<port-num>/cap_mask +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + + lid: (RO) Port LID + + rate: (RO) Port data rate (active width * active + speed) + + lid_mask_count: (RO) Port LID mask count + + sm_sl: (RO) Subnet manager SL for port's subnet + + sm_lid: (RO) Subnet manager LID for port's subnet + + state: (RO) Port state (DOWN, INIT, ARMED, ACTIVE or + ACTIVE_DEFER) + + phys_state: (RO) Port physical state (Sleep, Polling, + LinkUp, etc) + + cap_mask: (RO) Port capability mask. 2 bits here are + settable- IsCommunicationManagementSupported + (set when CM module is loaded) and IsSM (set via + open of issmN file). + + +What: /sys/class/infiniband/<device>/ports/<port-num>/link_layer +Date: Oct, 2010 +KernelVersion: v2.6.37 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Link layer type information (Infiniband or Ethernet type) + + +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/symbol_error +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_remote_physical_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_switch_relay_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/link_error_recovery +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_xmit_constraint_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_contraint_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/local_link_integrity_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/excessive_buffer_overrun_errors +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_xmit_data +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_data +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_xmit_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_rcv_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/unicast_rcv_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/unicast_xmit_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/multicast_rcv_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/multicast_xmit_packets +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/link_downed +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_xmit_discards +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/VL15_dropped +What: /sys/class/infiniband/<device>/ports/<port-num>/counters/port_xmit_wait +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + Errors info: + ----------- + + symbol_error: (RO) Total number of minor link errors detected on + one or more physical lanes. + + port_rcv_errors : (RO) Total number of packets containing an + error that were received on the port. + + port_rcv_remote_physical_errors : (RO) Total number of packets + marked with the EBP delimiter received on the port. + + port_rcv_switch_relay_errors : (RO) Total number of packets + received on the port that were discarded because they could not + be forwarded by the switch relay. + + link_error_recovery: (RO) Total number of times the Port + Training state machine has successfully completed the link error + recovery process. + + port_xmit_constraint_errors: (RO) Total number of packets not + transmitted from the switch physical port due to outbound raw + filtering or failing outbound partition or IP version check. + + port_rcv_constraint_errors: (RO) Total number of packets + received on the switch physical port that are discarded due to + inbound raw filtering or failing inbound partition or IP version + check. + + local_link_integrity_errors: (RO) The number of times that the + count of local physical errors exceeded the threshold specified + by LocalPhyErrors + + excessive_buffer_overrun_errors: (RO) This counter, indicates an + input buffer overrun. It indicates possible misconfiguration of + a port, either by the Subnet Manager (SM) or by user + intervention. It can also indicate hardware issues or extremely + poor link signal integrity + + Data info: + --------- + + port_xmit_data: (RO) Total number of data octets, divided by 4 + (lanes), transmitted on all VLs. This is 64 bit counter + + port_rcv_data: (RO) Total number of data octets, divided by 4 + (lanes), received on all VLs. This is 64 bit counter. + + port_xmit_packets: (RO) Total number of packets transmitted on + all VLs from this port. This may include packets with errors. + This is 64 bit counter. + + port_rcv_packets: (RO) Total number of packets (this may include + packets containing Errors. This is 64 bit counter. + + link_downed: (RO) Total number of times the Port Training state + machine has failed the link error recovery process and downed + the link. + + unicast_rcv_packets: (RO) Total number of unicast packets, + including unicast packets containing errors. + + unicast_xmit_packets: (RO) Total number of unicast packets + transmitted on all VLs from the port. This may include unicast + packets with errors. + + multicast_rcv_packets: (RO) Total number of multicast packets, + including multicast packets containing errors. + + multicast_xmit_packets: (RO) Total number of multicast packets + transmitted on all VLs from the port. This may include multicast + packets with errors. + + Misc info: + --------- + + port_xmit_discards: (RO) Total number of outbound packets + discarded by the port because the port is down or congested. + + VL15_dropped: (RO) Number of incoming VL15 packets dropped due + to resource limitations (e.g., lack of buffers) of the port. + + port_xmit_wait: (RO) The number of ticks during which the port + had data to transmit but no data was sent during the entire tick + (either because of insufficient credits or because of lack of + arbitration). + + Each of these files contains the corresponding value from the + port's Performance Management PortCounters attribute, as + described in the InfiniBand Architecture Specification. + + +What: /sys/class/infiniband/<device-name>/hw_counters/lifespan +What: /sys/class/infiniband/<device-name>/ports/<port-num>/hw_counters/lifespan +Date: May, 2016 +KernelVersion: 4.6 +Contact: linux-rdma@vger.kernel.org +Description: + The optional "hw_counters" subdirectory can be under either the + parent device or the port subdirectories or both. If present, + there are a list of counters provided by the hardware. They may + match some of the counters in the counters directory, but they + often include many other counters. In addition to the various + counters, there will be a file named "lifespan" that configures + how frequently the core should update the counters when they are + being accessed (counters are not updated if they are not being + accessed). The lifespan is in milliseconds and defaults to 10 + unless set to something else by the driver. Users may echo a + value between 0-10000 to the lifespan file to set the length + of time between updates in milliseconds. + + +What: /sys/class/infiniband/<hca>/ports/<port-number>/gid_attrs/ndevs/<gid-index> +Date: November 29, 2015 +KernelVersion: 4.4.0 +Contact: linux-rdma@vger.kernel.org +Description: The net-device's name associated with the GID resides + at index <gid-index>. + +What: /sys/class/infiniband/<hca>/ports/<port-number>/gid_attrs/types/<gid-index> +Date: November 29, 2015 +KernelVersion: 4.4.0 +Contact: linux-rdma@vger.kernel.org +Description: The RoCE type of the associated GID resides at index <gid-index>. + This could either be "IB/RoCE v1" for IB and RoCE v1 based GIDs + or "RoCE v2" for RoCE v2 based GIDs. + + +What: /sys/class/infiniband_mad/umadN/ibdev +What: /sys/class/infiniband_mad/umadN/port +What: /sys/class/infiniband_mad/issmN/ibdev +What: /sys/class/infiniband_mad/issmN/port +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + Each port of each InfiniBand device has a "umad" device and an + "issm" device attached. For example, a two-port HCA will have + two umad devices and two issm devices, while a switch will have + one device of each type (for switch port 0). + + ibdev: (RO) Show Infiniband (IB) device name + + port: (RO) Display port number + + +What: /sys/class/infiniband_mad/abi_version +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Value is incremented if any changes are made that break + userspace ABI compatibility of umad & issm devices. + + +What: /sys/class/infiniband_cm/ucmN/ibdev +Date: Oct, 2005 +KernelVersion: v2.6.14 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Display Infiniband (IB) device name + + +What: /sys/class/infiniband_cm/abi_version +Date: Oct, 2005 +KernelVersion: v2.6.14 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Value is incremented if any changes are made that break + userspace ABI compatibility of ucm devices. + + +What: /sys/class/infiniband_verbs/uverbsN/ibdev +What: /sys/class/infiniband_verbs/uverbsN/abi_version +Date: Sept, 2005 +KernelVersion: v2.6.14 +Contact: linux-rdma@vger.kernel.org +Description: + ibdev: (RO) Display Infiniband (IB) device name + + abi_version: (RO) Show ABI version of IB device specific + interfaces. + + +What: /sys/class/infiniband_verbs/abi_version +Date: Sep, 2005 +KernelVersion: v2.6.14 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) Value is incremented if any changes are made that break + userspace ABI compatibility of uverbs devices. + + +sysfs interface for Mellanox IB HCA low-level driver (mthca) +------------------------------------------------------------ + +What: /sys/class/infiniband/mthcaX/hw_rev +What: /sys/class/infiniband/mthcaX/hca_type +What: /sys/class/infiniband/mthcaX/board_id +Date: Apr, 2005 +KernelVersion: v2.6.12 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host Channel Adapter type: MT23108, MT25208 + (MT23108 compat mode), MT25208 or MT25204 + + board_id: (RO) Manufacturing board ID + + +sysfs interface for Chelsio T3 RDMA Driver (cxgb3) +-------------------------------------------------- + +What: /sys/class/infiniband/cxgb3_X/hw_rev +What: /sys/class/infiniband/cxgb3_X/hca_type +What: /sys/class/infiniband/cxgb3_X/board_id +Date: Feb, 2007 +KernelVersion: v2.6.21 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) HCA type. Here it is a driver short name. + It should normally match the name in its bus + driver structure (e.g. pci_driver::name). + + board_id: (RO) Manufacturing board id + + +sysfs interface for Mellanox ConnectX HCA IB driver (mlx4) +---------------------------------------------------------- + +What: /sys/class/infiniband/mlx4_X/hw_rev +What: /sys/class/infiniband/mlx4_X/hca_type +What: /sys/class/infiniband/mlx4_X/board_id +Date: Sep, 2007 +KernelVersion: v2.6.24 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host channel adapter type + + board_id: (RO) Manufacturing board ID + + +What: /sys/class/infiniband/mlx4_X/iov/ports/<port-num>/gids/<n> +What: /sys/class/infiniband/mlx4_X/iov/ports/<port-num>/admin_guids/<n> +What: /sys/class/infiniband/mlx4_X/iov/ports/<port-num>/pkeys/<n> +What: /sys/class/infiniband/mlx4_X/iov/ports/<port-num>/mcgs/ +What: /sys/class/infiniband/mlx4_X/iov/ports/<pci-slot-num>/ports/<m>/gid_idx/0 +What: /sys/class/infiniband/mlx4_X/iov/ports/<pci-slot-num>/ports/<m>/pkey_idx/<n> +Date: Aug, 2012 +KernelVersion: v3.6.15 +Contact: linux-rdma@vger.kernel.org +Description: + The sysfs iov directory is used to manage and examine the port + P_Key and guid paravirtualization. This directory is added only + for the master -- slaves do not have it. + + Under iov/ports, the administrator may examine the gid and P_Key + tables as they are present in the device (and as are seen in the + "network view" presented to the SM). + + The "pkeys" and "gids" subdirectories contain one file for each + entry in the port's P_Key or GID table respectively. For + example, ports/1/pkeys/10 contains the value at index 10 in port + 1's P_Key table. + + gids/<n>: (RO) The physical port gids n = 0..127 + + admin_guids/<n>: (RW) Allows examining or changing the + administrative state of a given GUID + n = 0..127 + + pkeys/<n>: (RO) Displays the contents of the physical + key table n = 0..126 + + mcgs/: (RO) Muticast group table + + <m>/gid_idx/0: (RO) Display the GID mapping m = 1..2 + + <m>/pkey_idx/<n>: (RW) Writable except for RoCE pkeys. + m = 1..2, n = 0..126 + + Under the iov/<pci slot number> + directories, the admin may map the index + numbers in the physical tables (as under + iov/ports) to the paravirtualized index + numbers that guests see. + + For example, if the administrator, for + port 1 on guest 2 maps physical pkey + index 10 to virtual index 1, then that + guest, whenever it uses its pkey index + 1, will actually be using the real pkey + index 10. + + +What: /sys/class/infiniband/mlx4_X/iov/<pci-slot-num>/ports/<m>/smi_enabled +What: /sys/class/infiniband/mlx4_X/iov/<pci-slot-num>/ports/<m>/enable_smi_admin +Date: May, 2014 +KernelVersion: v3.15.7 +Contact: linux-rdma@vger.kernel.org +Description: + Enabling QP0 on VFs for selected VF/port. By default, no VFs are + enabled for QP0 operation. + + smi_enabled: (RO) Indicates whether smi is currently enabled + for the indicated VF/port + + enable_smi_admin:(RW) Used by the admin to request that smi + capability be enabled or disabled for the + indicated VF/port. 0 = disable, 1 = enable. + + The requested enablement will occur at the next reset of the VF + (e.g. driver restart on the VM which owns the VF). + + +sysfs interface for NetEffect RNIC Low-Level iWARP driver (nes) +--------------------------------------------------------------- + +What: /sys/class/infiniband/nesX/hw_rev +What: /sys/class/infiniband/nesX/hca_type +What: /sys/class/infiniband/nesX/board_id +Date: Feb, 2008 +KernelVersion: v2.6.25 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host Channel Adapter type (NEX020) + + board_id: (RO) Manufacturing board id + + +sysfs interface for Chelsio T4/T5 RDMA driver (cxgb4) +----------------------------------------------------- + +What: /sys/class/infiniband/cxgb4_X/hw_rev +What: /sys/class/infiniband/cxgb4_X/hca_type +What: /sys/class/infiniband/cxgb4_X/board_id +Date: Apr, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Driver short name. Should normally match + the name in its bus driver structure (e.g. + pci_driver::name) + + board_id: (RO) Manufacturing board id. (Vendor + device + information) + + +sysfs interface for Intel IB driver qib +--------------------------------------- + +What: /sys/class/infiniband/qibX/version +What: /sys/class/infiniband/qibX/hw_rev +What: /sys/class/infiniband/qibX/hca_type +What: /sys/class/infiniband/qibX/board_id +What: /sys/class/infiniband/qibX/boardversion +What: /sys/class/infiniband/qibX/nctxts +What: /sys/class/infiniband/qibX/localbus_info +What: /sys/class/infiniband/qibX/tempsense +What: /sys/class/infiniband/qibX/serial +What: /sys/class/infiniband/qibX/nfreectxts +What: /sys/class/infiniband/qibX/chip_reset +Date: May, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + version: (RO) Display version information of installed software + and drivers. + + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host channel adapter type + + board_id: (RO) Manufacturing board id + + boardversion: (RO) Current version of the chip architecture + + nctxts: (RO) Return the number of user ports (contexts) + available + + localbus_info: (RO) Human readable localbus info + + tempsense: (RO) Display temp sense registers in decimal + + serial: (RO) Serial number of the HCA + + nfreectxts: (RO) The number of free user ports (contexts) + available. + + chip_reset: (WO) Reset the chip if possible by writing + "reset" to this file. Only allowed if no user + contexts are open that use chip resources. + + +What: /sys/class/infiniband/qibX/ports/N/sl2vl/[0-15] +Date: May, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + (RO) The directory contains 16 files numbered 0-15 that specify + the Service Level (SL). Listing the SL files returns the Virtual + Lane (VL) as programmed by the SL. + +What: /sys/class/infiniband/qibX/ports/N/CCMgtA/cc_settings_bin +What: /sys/class/infiniband/qibX/ports/N/CCMgtA/cc_table_bin +Date: May, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + Per-port congestion control. Both are binary attributes. + + cc_table_bin: (RO) Congestion control table size followed by + table entries. + + cc_settings_bin:(RO) Congestion settings: port control, control + map and an array of 16 entries for the + congestion entries - increase, timer, event log + trigger threshold and the minimum injection rate + delay. + +What: /sys/class/infiniband/qibX/ports/N/linkstate/loopback +What: /sys/class/infiniband/qibX/ports/N/linkstate/led_override +What: /sys/class/infiniband/qibX/ports/N/linkstate/hrtbt_enable +What: /sys/class/infiniband/qibX/ports/N/linkstate/status +What: /sys/class/infiniband/qibX/ports/N/linkstate/status_str +Date: May, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + [to be documented] + + loopback: (WO) + led_override: (WO) + hrtbt_enable: (RW) + status: (RO) + + status_str: (RO) Displays information about the link state, + possible cable/switch problems, and hardware + errors. Possible states are- "Initted", + "Present", "IB_link_up", "IB_configured" or + "Fatal_Hardware_Error". + +What: /sys/class/infiniband/qibX/ports/N/diag_counters/rc_resends +What: /sys/class/infiniband/qibX/ports/N/diag_counters/seq_naks +What: /sys/class/infiniband/qibX/ports/N/diag_counters/rdma_seq +What: /sys/class/infiniband/qibX/ports/N/diag_counters/rnr_naks +What: /sys/class/infiniband/qibX/ports/N/diag_counters/other_naks +What: /sys/class/infiniband/qibX/ports/N/diag_counters/rc_timeouts +What: /sys/class/infiniband/qibX/ports/N/diag_counters/look_pkts +What: /sys/class/infiniband/qibX/ports/N/diag_counters/pkt_drops +What: /sys/class/infiniband/qibX/ports/N/diag_counters/dma_wait +What: /sys/class/infiniband/qibX/ports/N/diag_counters/unaligned +Date: May, 2010 +KernelVersion: v2.6.35 +Contact: linux-rdma@vger.kernel.org +Description: + [to be documented] + + +sysfs interface for Mellanox Connect-IB HCA driver mlx5 +------------------------------------------------------- + +What: /sys/class/infiniband/mlx5_X/hw_rev +What: /sys/class/infiniband/mlx5_X/hca_type +What: /sys/class/infiniband/mlx5_X/reg_pages +What: /sys/class/infiniband/mlx5_X/fw_pages +Date: Jul, 2013 +KernelVersion: v3.11 +Contact: linux-rdma@vger.kernel.org +Description: + [to be documented] + + +sysfs interface for Cisco VIC (usNIC) Verbs Driver +-------------------------------------------------- + +What: /sys/class/infiniband/usnic_X/board_id +What: /sys/class/infiniband/usnic_X/config +What: /sys/class/infiniband/usnic_X/qp_per_vf +What: /sys/class/infiniband/usnic_X/max_vf +What: /sys/class/infiniband/usnic_X/cq_per_vf +What: /sys/class/infiniband/usnic_X/iface +Date: Sep, 2013 +KernelVersion: v3.14 +Contact: Christian Benvenuti <benve@cisco.com>, + Dave Goodell <dgoodell@cisco.com>, + linux-rdma@vger.kernel.org +Description: + + board_id: (RO) Manufacturing board id + + config: (RO) Report the configuration for this PF + + qp_per_vf: (RO) Queue pairs per virtual function. + + max_vf: (RO) Max virtual functions + + cq_per_vf: (RO) Completion queue per virtual function + + iface: (RO) Shows which network interface this usNIC + entry is associated to (visible with ifconfig). + +What: /sys/class/infiniband/usnic_X/qpn/summary +What: /sys/class/infiniband/usnic_X/qpn/context +Date: Sep, 2013 +KernelVersion: v3.14 +Contact: Christian Benvenuti <benve@cisco.com>, + Dave Goodell <dgoodell@cisco.com>, + linux-rdma@vger.kernel.org +Description: + [to be documented] + + +sysfs interface for Emulex RoCE HCA Driver +------------------------------------------ + +What: /sys/class/infiniband/ocrdmaX/hw_rev +Date: Feb, 2014 +KernelVersion: v3.14 +Description: + hw_rev: (RO) Hardware revision number + +What: /sys/class/infiniband/ocrdmaX/hca_type +Date: Jun, 2014 +KernelVersion: v3.16 +Contact: linux-rdma@vger.kernel.org +Description: + hca_type: (RO) Display FW version + + +sysfs interface for Intel Omni-Path driver (HFI1) +------------------------------------------------- + +What: /sys/class/infiniband/hfi1_X/hw_rev +What: /sys/class/infiniband/hfi1_X/board_id +What: /sys/class/infiniband/hfi1_X/nctxts +What: /sys/class/infiniband/hfi1_X/serial +What: /sys/class/infiniband/hfi1_X/chip_reset +What: /sys/class/infiniband/hfi1_X/boardversion +What: /sys/class/infiniband/hfi1_X/nfreectxts +What: /sys/class/infiniband/hfi1_X/tempsense +Date: May, 2016 +KernelVersion: v4.6 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + board_id: (RO) Manufacturing board id + + nctxts: (RO) Total contexts available. + + serial: (RO) Board serial number + + chip_reset: (WO) Write "reset" to this file to reset the + chip if possible. Only allowed if no user + contexts are open that use chip resources. + + boardversion: (RO) Human readable board info + + nfreectxts: (RO) The number of free user ports (contexts) + available. + + tempsense: (RO) Thermal sense information + + +What: /sys/class/infiniband/hfi1_X/ports/N/CCMgtA/cc_settings_bin +What: /sys/class/infiniband/hfi1_X/ports/N/CCMgtA/cc_table_bin +What: /sys/class/infiniband/hfi1_X/ports/N/CCMgtA/cc_prescan +Date: May, 2016 +KernelVersion: v4.6 +Contact: linux-rdma@vger.kernel.org +Description: + Per-port congestion control. + + cc_table_bin: (RO) CCA tables used by PSM2 Congestion control + table size followed by table entries. Binary + attribute. + + cc_settings_bin:(RO) Congestion settings: port control, control + map and an array of 16 entries for the + congestion entries - increase, timer, event log + trigger threshold and the minimum injection rate + delay. Binary attribute. + + cc_prescan: (RW) enable prescanning for faster BECN + response. Write "on" to enable and "off" to + disable. + +What: /sys/class/infiniband/hfi1_X/ports/N/sc2vl/[0-31] +What: /sys/class/infiniband/hfi1_X/ports/N/sl2sc/[0-31] +What: /sys/class/infiniband/hfi1_X/ports/N/vl2mtu/[0-15] +Date: May, 2016 +KernelVersion: v4.6 +Contact: linux-rdma@vger.kernel.org +Description: + sc2vl/: (RO) 32 files (0 - 31) used to translate sl->vl + + sl2sc/: (RO) 32 files (0 - 31) used to translate sl->sc + + vl2mtu/: (RO) 16 files (0 - 15) used to determine MTU for vl + + +What: /sys/class/infiniband/hfi1_X/sdma_N/cpu_list +What: /sys/class/infiniband/hfi1_X/sdma_N/vl +Date: Sept, 2016 +KernelVersion: v4.8 +Contact: linux-rdma@vger.kernel.org +Description: + sdma<N>/ contains one directory per sdma engine (0 - 15) + + cpu_list: (RW) List of cpus for user-process to sdma + engine assignment. + + vl: (RO) Displays the virtual lane (vl) the sdma + engine maps to. + + This interface gives the user control on the affinity settings + for the device. As an example, to set an sdma engine irq + affinity and thread affinity of a user processes to use the + sdma engine, which is "near" in terms of NUMA configuration, or + physical cpu location, the user will do: + + echo "3" > /proc/irq/<N>/smp_affinity_list + echo "4-7" > /sys/devices/.../sdma3/cpu_list + cat /sys/devices/.../sdma3/vl + 0 + echo "8" > /proc/irq/<M>/smp_affinity_list + echo "9-12" > /sys/devices/.../sdma4/cpu_list + cat /sys/devices/.../sdma4/vl + 1 + + to make sure that when a process runs on cpus 4,5,6, or 7, and + uses vl=0, then sdma engine 3 is selected by the driver, and + also the interrupt of the sdma engine 3 is steered to cpu 3. + Similarly, when a process runs on cpus 9,10,11, or 12 and sets + vl=1, then engine 4 will be selected and the irq of the sdma + engine 4 is steered to cpu 8. This assumes that in the above N + is the irq number of "sdma3", and M is irq number of "sdma4" in + the /proc/interrupts file. + + +sysfs interface for Intel(R) X722 iWARP i40iw driver +---------------------------------------------------- + +What: /sys/class/infiniband/i40iwX/hw_rev +What: /sys/class/infiniband/i40iwX/hca_type +What: /sys/class/infiniband/i40iwX/board_id +Date: Jan, 2016 +KernelVersion: v4.10 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Show HCA type (I40IW) + + board_id: (RO) I40IW board ID + + +sysfs interface for QLogic qedr NIC Driver +------------------------------------------ + +What: /sys/class/infiniband/qedrX/hw_rev +What: /sys/class/infiniband/qedrX/hca_type +Date: Oct, 2016 +KernelVersion: v4.10 +Contact: linux-rdma@vger.kernel.org +Description: + + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Display HCA type + + +sysfs interface for VMware Paravirtual RDMA driver +-------------------------------------------------- + +What: /sys/class/infiniband/vmw_pvrdmaX/hw_rev +What: /sys/class/infiniband/vmw_pvrdmaX/hca_type +What: /sys/class/infiniband/vmw_pvrdmaX/board_id +Date: Oct, 2016 +KernelVersion: v4.10 +Contact: linux-rdma@vger.kernel.org +Description: + + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host channel adapter type + + board_id: (RO) Display PVRDMA manufacturing board ID + + +sysfs interface for Broadcom NetXtreme-E RoCE driver +---------------------------------------------------- + +What: /sys/class/infiniband/bnxt_reX/hw_rev +What: /sys/class/infiniband/bnxt_reX/hca_type +Date: Feb, 2017 +KernelVersion: v4.11 +Contact: linux-rdma@vger.kernel.org +Description: + hw_rev: (RO) Hardware revision number + + hca_type: (RO) Host channel adapter type diff --git a/Documentation/ABI/testing/sysfs-class-infiniband b/Documentation/ABI/testing/sysfs-class-infiniband deleted file mode 100644 index a86abe66a316..000000000000 --- a/Documentation/ABI/testing/sysfs-class-infiniband +++ /dev/null @@ -1,16 +0,0 @@ -What: /sys/class/infiniband/<hca>/ports/<port-number>/gid_attrs/ndevs/<gid-index> -Date: November 29, 2015 -KernelVersion: 4.4.0 -Contact: linux-rdma@vger.kernel.org -Description: The net-device's name associated with the GID resides - at index <gid-index>. - -What: /sys/class/infiniband/<hca>/ports/<port-number>/gid_attrs/types/<gid-index> -Date: November 29, 2015 -KernelVersion: 4.4.0 -Contact: linux-rdma@vger.kernel.org -Description: The RoCE type of the associated GID resides at index <gid-index>. - This could either be "IB/RoCE v1" for IB and RoCE v1 based GODs - or "RoCE v2" for RoCE v2 based GIDs. - - diff --git a/Documentation/infiniband/sysfs.txt b/Documentation/infiniband/sysfs.txt index 77570d16b170..9fab5062f84b 100644 --- a/Documentation/infiniband/sysfs.txt +++ b/Documentation/infiniband/sysfs.txt @@ -1,129 +1,4 @@ SYSFS FILES - For each InfiniBand device, the InfiniBand drivers create the - following files under /sys/class/infiniband/<device name>: - - node_type - Node type (CA, switch or router) - node_guid - Node GUID - sys_image_guid - System image GUID - - In addition, there is a "ports" subdirectory, with one subdirectory - for each port. For example, if mthca0 is a 2-port HCA, there will - be two directories: - - /sys/class/infiniband/mthca0/ports/1 - /sys/class/infiniband/mthca0/ports/2 - - (A switch will only have a single "0" subdirectory for switch port - 0; no subdirectory is created for normal switch ports) - - In each port subdirectory, the following files are created: - - cap_mask - Port capability mask - lid - Port LID - lid_mask_count - Port LID mask count - rate - Port data rate (active width * active speed) - sm_lid - Subnet manager LID for port's subnet - sm_sl - Subnet manager SL for port's subnet - state - Port state (DOWN, INIT, ARMED, ACTIVE or ACTIVE_DEFER) - phys_state - Port physical state (Sleep, Polling, LinkUp, etc) - - There is also a "counters" subdirectory, with files - - VL15_dropped - excessive_buffer_overrun_errors - link_downed - link_error_recovery - local_link_integrity_errors - port_rcv_constraint_errors - port_rcv_data - port_rcv_errors - port_rcv_packets - port_rcv_remote_physical_errors - port_rcv_switch_relay_errors - port_xmit_constraint_errors - port_xmit_data - port_xmit_discards - port_xmit_packets - symbol_error - - Each of these files contains the corresponding value from the port's - Performance Management PortCounters attribute, as described in - section 16.1.3.5 of the InfiniBand Architecture Specification. - - The "pkeys" and "gids" subdirectories contain one file for each - entry in the port's P_Key or GID table respectively. For example, - ports/1/pkeys/10 contains the value at index 10 in port 1's P_Key - table. - - There is an optional "hw_counters" subdirectory that may be under either - the parent device or the port subdirectories or both. If present, - there are a list of counters provided by the hardware. They may match - some of the counters in the counters directory, but they often include - many other counters. In addition to the various counters, there will - be a file named "lifespan" that configures how frequently the core - should update the counters when they are being accessed (counters are - not updated if they are not being accessed). The lifespan is in milli- - seconds and defaults to 10 unless set to something else by the driver. - Users may echo a value between 0 - 10000 to the lifespan file to set - the length of time between updates in milliseconds. - -MTHCA - - The Mellanox HCA driver also creates the files: - - hw_rev - Hardware revision number - fw_ver - Firmware version - hca_type - HCA type: "MT23108", "MT25208 (MT23108 compat mode)", - or "MT25208" - -HFI1 - - The hfi1 driver also creates these additional files: - - hw_rev - hardware revision - board_id - manufacturing board id - tempsense - thermal sense information - serial - board serial number - nfreectxts - number of free user contexts - nctxts - number of allowed contexts (PSM2) - chip_reset - diagnostic (root only) - boardversion - board version - - sdma<N>/ - one directory per sdma engine (0 - 15) - sdma<N>/cpu_list - read-write, list of cpus for user-process to sdma - engine assignment. - sdma<N>/vl - read-only, vl the sdma engine maps to. - - The new interface will give the user control on the affinity settings - for the hfi1 device. - As an example, to set an sdma engine irq affinity and thread affinity - of a user processes to use the sdma engine, which is "near" in terms - of NUMA configuration, or physical cpu location, the user will do: - - echo "3" > /proc/irq/<N>/smp_affinity_list - echo "4-7" > /sys/devices/.../sdma3/cpu_list - cat /sys/devices/.../sdma3/vl - 0 - echo "8" > /proc/irq/<M>/smp_affinity_list - echo "9-12" > /sys/devices/.../sdma4/cpu_list - cat /sys/devices/.../sdma4/vl - 1 - - to make sure that when a process runs on cpus 4,5,6, or 7, - and uses vl=0, then sdma engine 3 is selected by the driver, - and also the interrupt of the sdma engine 3 is steered to cpu 3. - Similarly, when a process runs on cpus 9,10,11, or 12 and sets vl=1, - then engine 4 will be selected and the irq of the sdma engine 4 is - steered to cpu 8. - This assumes that in the above N is the irq number of "sdma3", - and M is irq number of "sdma4" in the /proc/interrupts file. - - ports/1/ - CCMgtA/ - cc_settings_bin - CCA tables used by PSM2 - cc_table_bin - cc_prescan - enable prescaning for faster BECN response - sc2v/ - 32 files (0 - 31) used to translate sl->vl - sl2sc/ - 32 files (0 - 31) used to translate sl->sc - vl2mtu/ - 16 (0 - 15) files used to determine MTU for vl +The sysfs interface has moved to +Documentation/ABI/stable/sysfs-class-infiniband. |