diff options
Diffstat (limited to 'Documentation/ABI/testing/sysfs-driver-hid-roccat-koneplus')
-rw-r--r-- | Documentation/ABI/testing/sysfs-driver-hid-roccat-koneplus | 96 |
1 files changed, 0 insertions, 96 deletions
diff --git a/Documentation/ABI/testing/sysfs-driver-hid-roccat-koneplus b/Documentation/ABI/testing/sysfs-driver-hid-roccat-koneplus deleted file mode 100644 index 7bd776f9c3c7..000000000000 --- a/Documentation/ABI/testing/sysfs-driver-hid-roccat-koneplus +++ /dev/null @@ -1,96 +0,0 @@ -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/actual_profile -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: The integer value of this attribute ranges from 0-4. - When read, this attribute returns the number of the actual - profile. This value is persistent, so its equivalent to the - profile that's active when the mouse is powered on next time. - When written, this file sets the number of the startup profile - and the mouse activates this profile immediately. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/info -Date: November 2012 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: When read, this file returns general data like firmware version. - When written, the device can be reset. - The data is 8 bytes long. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/macro -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: The mouse can store a macro with max 500 key/button strokes - internally. - When written, this file lets one set the sequence for a specific - button for a specific profile. Button and profile numbers are - included in written data. The data has to be 2082 bytes long. - This file is writeonly. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile_buttons -Date: August 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: The mouse can store 5 profiles which can be switched by the - press of a button. A profile is split in settings and buttons. - profile_buttons holds information about button layout. - When written, this file lets one write the respective profile - buttons back to the mouse. The data has to be 77 bytes long. - The mouse will reject invalid data. - Which profile to write is determined by the profile number - contained in the data. - Before reading this file, control has to be written to select - which profile to read. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/profile_settings -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: The mouse can store 5 profiles which can be switched by the - press of a button. A profile is split in settings and buttons. - profile_settings holds information like resolution, sensitivity - and light effects. - When written, this file lets one write the respective profile - settings back to the mouse. The data has to be 43 bytes long. - The mouse will reject invalid data. - Which profile to write is determined by the profile number - contained in the data. - Before reading this file, control has to be written to select - which profile to read. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/sensor -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: The mouse has a tracking- and a distance-control-unit. These - can be activated/deactivated and the lift-off distance can be - set. The data has to be 6 bytes long. - This file is writeonly. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/talk -Date: May 2011 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: Used to active some easy* functions of the mouse from outside. - The data has to be 16 bytes long. - This file is writeonly. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/tcu -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: When written a calibration process for the tracking control unit - can be initiated/cancelled. Also lets one read/write sensor - registers. - The data has to be 4 bytes long. -Users: http://roccat.sourceforge.net - -What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/koneplus/roccatkoneplus<minor>/tcu_image -Date: October 2010 -Contact: Stefan Achatz <erazor_de@users.sourceforge.net> -Description: When read the mouse returns a 30x30 pixel image of the - sampled underground. This works only in the course of a - calibration process initiated with tcu. - The returned data is 1028 bytes in size. - This file is readonly. -Users: http://roccat.sourceforge.net |