+README on the ADC/Touchscreen Controller
+========================================
+
+The LH79524 and LH7A404 include a built-in Analog to Digital
+controller (ADC) that is used to process input from a touchscreen.
+The driver only implements a four-wire touch panel protocol.
+
+The touchscreen driver is maintenance free except for the pen-down or
+touch threshold. Some resistive displays and board combinations may
+require tuning of this threshold. The driver exposes some of it's
+internal state in the sys filesystem. If the kernel is configured
+with it, CONFIG_SYSFS, and sysfs is mounted at /sys, there will be a
+directory
+
+ /sys/devices/platform/adc-lh7.0
+
+containing these files.
+
+ -r--r--r-- 1 root root 4096 Jan 1 00:00 samples
+ -rw-r--r-- 1 root root 4096 Jan 1 00:00 threshold
+ -r--r--r-- 1 root root 4096 Jan 1 00:00 threshold_range
+
+The threshold is the current touch threshold. It defaults to 750 on
+most targets.
+
+ # cat threshold
+ 750
+
+The threshold_range contains the range of valid values for the
+threshold. Values outside of this range will be silently ignored.
+
+ # cat threshold_range
+ 0 1023
+
+To change the threshold, write a value to the threshold file.
+
+ # echo 500 > threshold
+ # cat threshold
+ 500
+
+The samples file contains the most recently sampled values from the
+ADC. There are 12. Below are typical of the last sampled values when
+the pen has been released. The first two and last two samples are for
+detecting whether or not the pen is down. The third through sixth are
+X coordinate samples. The seventh through tenth are Y coordinate
+samples.
+
+ # cat samples
+ 1023 1023 0 0 0 0 530 529 530 529 1023 1023
+
+To determine a reasonable threshold, press on the touch panel with an
+appropriate stylus and read the values from samples.
+
+ # cat samples
+ 1023 676 92 103 101 102 855 919 922 922 1023 679
+
+The first and eleventh samples are discarded. Thus, the important
+values are the second and twelfth which are used to determine if the
+pen is down. When both are below the threshold, the driver registers
+that the pen is down. When either is above the threshold, it
+registers then pen is up.