diff --git a/Documentation/hwmon/adm1021 b/Documentation/hwmon/adm1021
index 03d02bfb3df1..02ad96cf9b2b 100644
--- a/Documentation/hwmon/adm1021
+++ b/Documentation/hwmon/adm1021
@@ -14,10 +14,6 @@ Supported chips:
Prefix: 'gl523sm'
Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
Datasheet:
- * Intel Xeon Processor
- Prefix: - any other - may require 'force_adm1021' parameter
- Addresses scanned: none
- Datasheet: Publicly available at Intel website
* Maxim MAX1617
Prefix: 'max1617'
Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
@@ -91,21 +87,27 @@ will do no harm, but will return 'old' values. It is possible to make
ADM1021-clones do faster measurements, but there is really no good reason
for that.
-Xeon support
-------------
-Some Xeon processors have real max1617, adm1021, or compatible chips
-within them, with two temperature sensors.
+Netburst-based Xeon support
+---------------------------
-Other Xeons have chips with only one sensor.
+Some Xeon processors based on the Netburst (early Pentium 4, from 2001 to
+2003) microarchitecture had real MAX1617, ADM1021, or compatible chips
+within them, with two temperature sensors. Other Xeon processors of this
+era (with 400 MHz FSB) had chips with only one temperature sensor.
-If you have a Xeon, and the adm1021 module loads, and both temperatures
-appear valid, then things are good.
+If you have such an old Xeon, and you get two valid temperatures when
+loading the adm1021 module, then things are good.
-If the adm1021 module doesn't load, you should try this:
- modprobe adm1021 force_adm1021=BUS,ADDRESS
- ADDRESS can only be 0x18, 0x1a, 0x29, 0x2b, 0x4c, or 0x4e.
+If nothing happens when loading the adm1021 module, and you are certain
+that your specific Xeon processor model includes compatible sensors, you
+will have to explicitly instantiate the sensor chips from user-space. See
+method 4 in Documentation/i2c/instantiating-devices. Possible slave
+addresses are 0x18, 0x1a, 0x29, 0x2b, 0x4c, or 0x4e. It is likely that
+only temp2 will be correct and temp1 will have to be ignored.
-If you have dual Xeons you may have appear to have two separate
-adm1021-compatible chips, or two single-temperature sensors, at distinct
-addresses.
+Previous generations of the Xeon processor (based on Pentium II/III)
+didn't have these sensors. Next generations of Xeon processors (533 MHz
+FSB and faster) lost them, until the Core-based generation which
+introduced integrated digital thermal sensors. These are supported by
+the coretemp driver.
diff --git a/Documentation/hwmon/lm90 b/Documentation/hwmon/lm90
index fa475c0a48a3..f3efd18e87f4 100644
--- a/Documentation/hwmon/lm90
+++ b/Documentation/hwmon/lm90
@@ -32,6 +32,16 @@ Supported chips:
Addresses scanned: I2C 0x4c and 0x4d
Datasheet: Publicly available at the ON Semiconductor website
http://www.onsemi.com/PowerSolutions/product.do?id=ADT7461
+ * Analog Devices ADT7461A
+ Prefix: 'adt7461a'
+ Addresses scanned: I2C 0x4c and 0x4d
+ Datasheet: Publicly available at the ON Semiconductor website
+ http://www.onsemi.com/PowerSolutions/product.do?id=ADT7461A
+ * ON Semiconductor NCT1008
+ Prefix: 'nct1008'
+ Addresses scanned: I2C 0x4c and 0x4d
+ Datasheet: Publicly available at the ON Semiconductor website
+ http://www.onsemi.com/PowerSolutions/product.do?id=NCT1008
* Maxim MAX6646
Prefix: 'max6646'
Addresses scanned: I2C 0x4d
@@ -149,7 +159,7 @@ ADM1032:
* ALERT is triggered by open remote sensor.
* SMBus PEC support for Write Byte and Receive Byte transactions.
-ADT7461:
+ADT7461, ADT7461A, NCT1008:
* Extended temperature range (breaks compatibility)
* Lower resolution for remote temperature
@@ -195,9 +205,9 @@ are exported, one for each channel, but these values are of course linked.
Only the local hysteresis can be set from user-space, and the same delta
applies to the remote hysteresis.
-The lm90 driver will not update its values more frequently than every
-other second; reading them more often will do no harm, but will return
-'old' values.
+The lm90 driver will not update its values more frequently than configured with
+the update_interval attribute; reading them more often will do no harm, but will
+return 'old' values.
SMBus Alert Support
-------------------
@@ -205,11 +215,12 @@ SMBus Alert Support
This driver has basic support for SMBus alert. When an alert is received,
the status register is read and the faulty temperature channel is logged.
-The Analog Devices chips (ADM1032 and ADT7461) do not implement the SMBus
-alert protocol properly so additional care is needed: the ALERT output is
-disabled when an alert is received, and is re-enabled only when the alarm
-is gone. Otherwise the chip would block alerts from other chips in the bus
-as long as the alarm is active.
+The Analog Devices chips (ADM1032, ADT7461 and ADT7461A) and ON
+Semiconductor chips (NCT1008) do not implement the SMBus alert protocol
+properly so additional care is needed: the ALERT output is disabled when
+an alert is received, and is re-enabled only when the alarm is gone.
+Otherwise the chip would block alerts from other chips in the bus as long
+as the alarm is active.
PEC Support
-----------