diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index 2f0ddc15b5ac..9c647bd7c5a9 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -81,6 +81,9 @@ This defines trickle and fast charges. For batteries that are already charged or discharging, 'n/a' can be displayed (or 'unknown', if the status is not known). +AUTHENTIC - indicates the power supply (battery or charger) connected +to the platform is authentic(1) or non authentic(0). + HEALTH - represents health of the battery, values corresponds to POWER_SUPPLY_HEALTH_*, defined in battery.h. @@ -113,8 +116,12 @@ be negative; there is no empty or full value. It is only useful for relative, time-based measurements. CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger. +CONSTANT_CHARGE_CURRENT_MAX - maximum charge current supported by the +power supply object. CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger. +CONSTANT_CHARGE_VOLTAGE_MAX - maximum charge voltage supported by the +power supply object. ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. |