summaryrefslogtreecommitdiff
path: root/drivers/thermal
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/armada_thermal.c58
1 files changed, 58 insertions, 0 deletions
diff --git a/drivers/thermal/armada_thermal.c b/drivers/thermal/armada_thermal.c
index f84d9f077fe2..e65c5e442ed5 100644
--- a/drivers/thermal/armada_thermal.c
+++ b/drivers/thermal/armada_thermal.c
@@ -35,6 +35,15 @@
#define PMU_TDC0_OTF_CAL_MASK (0x1 << 30)
#define PMU_TDC0_START_CAL_MASK (0x1 << 25)
+#define A375_Z1_CAL_RESET_LSB 0x8011e214
+#define A375_Z1_CAL_RESET_MSB 0x30a88019
+#define A375_Z1_WORKAROUND_BIT BIT(9)
+
+#define A375_UNIT_CONTROL_SHIFT 27
+#define A375_UNIT_CONTROL_MASK 0x7
+#define A375_READOUT_INVERT BIT(15)
+#define A375_HW_RESETn BIT(8)
+
struct armada_thermal_data;
/* Marvell EBU Thermal Sensor Dev Structure */
@@ -110,6 +119,36 @@ static void armada370_init_sensor(struct platform_device *pdev,
mdelay(10);
}
+static void armada375_init_sensor(struct platform_device *pdev,
+ struct armada_thermal_priv *priv)
+{
+ unsigned long reg;
+ bool quirk_needed =
+ !!of_device_is_compatible(pdev->dev.of_node,
+ "marvell,armada375-z1-thermal");
+
+ if (quirk_needed) {
+ /* Ensure these registers have the default (reset) values */
+ writel(A375_Z1_CAL_RESET_LSB, priv->control);
+ writel(A375_Z1_CAL_RESET_MSB, priv->control + 0x4);
+ }
+
+ reg = readl(priv->control + 4);
+ reg &= ~(A375_UNIT_CONTROL_MASK << A375_UNIT_CONTROL_SHIFT);
+ reg &= ~A375_READOUT_INVERT;
+ reg &= ~A375_HW_RESETn;
+
+ if (quirk_needed)
+ reg |= A375_Z1_WORKAROUND_BIT;
+
+ writel(reg, priv->control + 4);
+ mdelay(20);
+
+ reg |= A375_HW_RESETn;
+ writel(reg, priv->control + 4);
+ mdelay(50);
+}
+
static bool armada_is_valid(struct armada_thermal_priv *priv)
{
unsigned long reg = readl_relaxed(priv->sensor);
@@ -170,6 +209,17 @@ static const struct armada_thermal_data armada370_data = {
.coef_div = 13825,
};
+static const struct armada_thermal_data armada375_data = {
+ .is_valid = armada_is_valid,
+ .init_sensor = armada375_init_sensor,
+ .is_valid_shift = 10,
+ .temp_shift = 0,
+ .temp_mask = 0x1ff,
+ .coef_b = 3171900000UL,
+ .coef_m = 10000000UL,
+ .coef_div = 13616,
+};
+
static const struct of_device_id armada_thermal_id_table[] = {
{
.compatible = "marvell,armadaxp-thermal",
@@ -180,6 +230,14 @@ static const struct of_device_id armada_thermal_id_table[] = {
.data = &armada370_data,
},
{
+ .compatible = "marvell,armada375-thermal",
+ .data = &armada375_data,
+ },
+ {
+ .compatible = "marvell,armada375-z1-thermal",
+ .data = &armada375_data,
+ },
+ {
/* sentinel */
},
};