summaryrefslogtreecommitdiff
path: root/drivers/thermal
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal')
-rw-r--r--drivers/thermal/imx_thermal.c50
1 files changed, 40 insertions, 10 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index d16c33c7f3f0..c9a55b0214e5 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -55,12 +55,6 @@ enum imx_thermal_trip {
*/
#define IMX_TEMP_PASSIVE 85000
-/*
- * The maximum die temperature on imx parts is 105C, let's give some cushion
- * for noise and possible temperature rise between measurements.
- */
-#define IMX_TEMP_CRITICAL 100000
-
#define IMX_POLLING_DELAY 2000 /* millisecond */
#define IMX_PASSIVE_DELAY 1000
@@ -70,6 +64,8 @@ struct imx_thermal_data {
enum thermal_device_mode mode;
struct regmap *tempmon;
int c1, c2; /* See formula in imx_get_sensor_data() */
+ unsigned long temp_passive;
+ unsigned long temp_critical;
};
static int imx_get_temp(struct thermal_zone_device *tz, unsigned long *temp)
@@ -156,15 +152,35 @@ static int imx_get_trip_type(struct thermal_zone_device *tz, int trip,
static int imx_get_crit_temp(struct thermal_zone_device *tz,
unsigned long *temp)
{
- *temp = IMX_TEMP_CRITICAL;
+ struct imx_thermal_data *data = tz->devdata;
+
+ *temp = data->temp_critical;
return 0;
}
static int imx_get_trip_temp(struct thermal_zone_device *tz, int trip,
unsigned long *temp)
{
- *temp = (trip == IMX_TRIP_PASSIVE) ? IMX_TEMP_PASSIVE :
- IMX_TEMP_CRITICAL;
+ struct imx_thermal_data *data = tz->devdata;
+
+ *temp = (trip == IMX_TRIP_PASSIVE) ? data->temp_passive :
+ data->temp_critical;
+ return 0;
+}
+
+static int imx_set_trip_temp(struct thermal_zone_device *tz, int trip,
+ unsigned long temp)
+{
+ struct imx_thermal_data *data = tz->devdata;
+
+ if (trip == IMX_TRIP_CRITICAL)
+ return -EPERM;
+
+ if (temp > IMX_TEMP_PASSIVE)
+ return -EINVAL;
+
+ data->temp_passive = temp;
+
return 0;
}
@@ -211,6 +227,7 @@ static const struct thermal_zone_device_ops imx_tz_ops = {
.get_trip_type = imx_get_trip_type,
.get_trip_temp = imx_get_trip_temp,
.get_crit_temp = imx_get_crit_temp,
+ .set_trip_temp = imx_set_trip_temp,
};
static int imx_get_sensor_data(struct platform_device *pdev)
@@ -267,6 +284,18 @@ static int imx_get_sensor_data(struct platform_device *pdev)
data->c1 = 1000 * (t1 - t2) / (n1 - n2);
data->c2 = 1000 * t2 - data->c1 * n2;
+ /*
+ * Set the default passive cooling trip point to 20 °C below the
+ * maximum die temperature. Can be changed from userspace.
+ */
+ data->temp_passive = 1000 * (t2 - 20);
+
+ /*
+ * The maximum die temperature is t2, let's give 5 °C cushion
+ * for noise and possible temperature rise between measurements.
+ */
+ data->temp_critical = 1000 * (t2 - 5);
+
return 0;
}
@@ -314,7 +343,8 @@ static int imx_thermal_probe(struct platform_device *pdev)
}
data->tz = thermal_zone_device_register("imx_thermal_zone",
- IMX_TRIP_NUM, 0, data,
+ IMX_TRIP_NUM,
+ BIT(IMX_TRIP_PASSIVE), data,
&imx_tz_ops, NULL,
IMX_PASSIVE_DELAY,
IMX_POLLING_DELAY);