commit 7fc10de8d49a748c476532c9d8e8fe19e548dd67 upstream.
Since most of the SD ADCs have the option of reseting the serial
interface by sending a number of SCLKs with CS = 0 and DIN = 1,
a dedicated function that can do this is usefull.
Needed for the patch: iio: ad7793: Fix the serial interface reset
Signed-off-by: Dragos Bogdan <dragos.bogdan@analog.com>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
|
|
The original info_mask is going away in favour of the broken out versions.
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
|
|
Most devices from the Analog Devices Sigma Delta family use a similar scheme for
communication with the device. This includes register access, as well as trigger
handling. But each device sub-family has different features and different
register layouts (some even have no registers at all) and thus it is impractical
to try to support all of the devices by the same driver. This patch adds a
common base library for Sigma Delta converter devices. It will be used by
individual drivers.
This code is mostly based on the three existing Sigma Delta drivers the AD7192,
AD7780 and AD7793, but has been improved for more robustness and flexibility.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>