From 9a0b37926595b57c4b5fc56aa6fd243bed4ee4eb Mon Sep 17 00:00:00 2001 From: Clemens Ladisch Date: Mon, 4 Oct 2010 13:25:13 +0200 Subject: ALSA: oxygen: fix input monitor dB scale The input monitor half volume bit results in a factor of 0.5, so the minimum scale value should be -6 dB. Signed-off-by: Clemens Ladisch Signed-off-by: Takashi Iwai --- sound/pci/oxygen/oxygen_mixer.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/sound/pci/oxygen/oxygen_mixer.c b/sound/pci/oxygen/oxygen_mixer.c index 7d40ba8db9fc..2849b36f5f7e 100644 --- a/sound/pci/oxygen/oxygen_mixer.c +++ b/sound/pci/oxygen/oxygen_mixer.c @@ -708,7 +708,7 @@ static int ac97_fp_rec_volume_put(struct snd_kcontrol *ctl, .private_value = ((codec) << 24) | ((stereo) << 16) | (index), \ } -static DECLARE_TLV_DB_SCALE(monitor_db_scale, -1000, 1000, 0); +static DECLARE_TLV_DB_SCALE(monitor_db_scale, -600, 600, 0); static DECLARE_TLV_DB_SCALE(ac97_db_scale, -3450, 150, 0); static DECLARE_TLV_DB_SCALE(ac97_rec_db_scale, 0, 150, 0); -- cgit v1.2.3