From b735f41dcb06ae06acab2618b8814fe2dd1fca90 Mon Sep 17 00:00:00 2001 From: Johan Hovold Date: Fri, 8 Feb 2019 15:04:25 +0100 Subject: dt-bindings: regulator: update fixed-regulator example Fixed regulators do not have associated bus addresses and are typically placed directly under the root node where their names must still be unique despite not having a unit address. Fix the malformed example node which had a unit address but no "reg" property by dropping the unit address. Also, try to make the example more useful by using the recommended generic node name "regulator", but with a suffix reflecting the regulator name in order to make it unique. Signed-off-by: Johan Hovold Signed-off-by: Mark Brown --- Documentation/devicetree/bindings/regulator/fixed-regulator.yaml | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'Documentation/devicetree/bindings/regulator') diff --git a/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml b/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml index a7607b0baab7..d289c2f7455a 100644 --- a/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml +++ b/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml @@ -52,9 +52,9 @@ required: examples: - | - abc: fixedregulator@0 { + reg_1v8: regulator-1v8 { compatible = "regulator-fixed"; - regulator-name = "fixed-supply"; + regulator-name = "1v8"; regulator-min-microvolt = <1800000>; regulator-max-microvolt = <1800000>; gpio = <&gpio1 16 0>; -- cgit v1.2.3