From faaa44955dedc661f083636d816af90975a359ee Mon Sep 17 00:00:00 2001 From: Irina Tirdea Date: Wed, 29 Apr 2015 21:16:39 +0300 Subject: iio: core: Introduce IIO_CHAN_INFO_OVERSAMPLING_RATIO Some magnetometers can perform a number of repetitions in HW for each measurement to increase accuracy. One example is Bosch BMC150: http://ae-bst.resource.bosch.com/media/products/dokumente/bmc150/BST-BMC150-DS000-04.pdf. Introduce an interface to set the oversampling ratio for these devices. Signed-off-by: Irina Tirdea Signed-off-by: Jonathan Cameron --- drivers/iio/industrialio-core.c | 1 + 1 file changed, 1 insertion(+) (limited to 'drivers') diff --git a/drivers/iio/industrialio-core.c b/drivers/iio/industrialio-core.c index 7c98bc1504e6..dfa81db3b910 100644 --- a/drivers/iio/industrialio-core.c +++ b/drivers/iio/industrialio-core.c @@ -129,6 +129,7 @@ static const char * const iio_chan_info_postfix[] = { [IIO_CHAN_INFO_DEBOUNCE_COUNT] = "debounce_count", [IIO_CHAN_INFO_DEBOUNCE_TIME] = "debounce_time", [IIO_CHAN_INFO_CALIBEMISSIVITY] = "calibemissivity", + [IIO_CHAN_INFO_OVERSAMPLING_RATIO] = "oversampling_ratio", }; /** -- cgit v1.2.3