[ { "EventCode": "0x10016", "EventName": "PM_VSU0_ISSUE", "BriefDescription": "VSU instruction issued to VSU pipe 0." }, { "EventCode": "0x1001C", "EventName": "PM_ULTRAVISOR_INST_CMPL", "BriefDescription": "PowerPC instruction completed while the thread was in ultravisor state." }, { "EventCode": "0x100F0", "EventName": "PM_CYC", "BriefDescription": "Processor cycles." }, { "EventCode": "0x10134", "EventName": "PM_MRK_ST_DONE_L2", "BriefDescription": "Marked store completed in L2." }, { "EventCode": "0x1505E", "EventName": "PM_LD_HIT_L1", "BriefDescription": "Load finished without experiencing an L1 miss." }, { "EventCode": "0x1F056", "EventName": "PM_DISP_SS0_2_INSTR_CYC", "BriefDescription": "Cycles in which Superslice 0 dispatches either 1 or 2 instructions." }, { "EventCode": "0x10066", "EventName": "PM_ADJUNCT_CYC", "BriefDescription": "Cycles in which the thread is in Adjunct state. MSR[S HV PR] bits = 011." }, { "EventCode": "0x101E4", "EventName": "PM_MRK_L1_ICACHE_MISS", "BriefDescription": "Marked instruction suffered an instruction cache miss." }, { "EventCode": "0x101EA", "EventName": "PM_MRK_L1_RELOAD_VALID", "BriefDescription": "Marked demand reload." }, { "EventCode": "0x100F4", "EventName": "PM_FLOP_CMPL", "BriefDescription": "Floating Point Operations Completed. Includes any type. It counts once for each 1, 2, 4 or 8 flop instruction. Use PM_1|2|4|8_FLOP_CMPL events to count flops." }, { "EventCode": "0x100FA", "EventName": "PM_RUN_LATCH_ANY_THREAD_CYC", "BriefDescription": "Cycles when at least one thread has the run latch set." }, { "EventCode": "0x100FC", "EventName": "PM_LD_REF_L1", "BriefDescription": "All L1 D cache load references counted at finish, gated by reject. In P9 and earlier this event counted only cacheable loads but in P10 both cacheable and non-cacheable loads are included." }, { "EventCode": "0x2000C", "EventName": "PM_RUN_LATCH_ALL_THREADS_CYC", "BriefDescription": "Cycles when the run latch is set for all threads." }, { "EventCode": "0x2E010", "EventName": "PM_ADJUNCT_INST_CMPL", "BriefDescription": "PowerPC instruction completed while the thread was in Adjunct state." }, { "EventCode": "0x2E014", "EventName": "PM_STCX_FIN", "BriefDescription": "Conditional store instruction (STCX) finished. LARX and STCX are instructions used to acquire a lock." }, { "EventCode": "0x20130", "EventName": "PM_MRK_INST_DECODED", "BriefDescription": "An instruction was marked at decode time. Random Instruction Sampling (RIS) only." }, { "EventCode": "0x20132", "EventName": "PM_MRK_DFU_ISSUE", "BriefDescription": "The marked instruction was a decimal floating point operation issued to the VSU. Measured at issue time." }, { "EventCode": "0x20134", "EventName": "PM_MRK_FXU_ISSUE", "BriefDescription": "The marked instruction was a fixed point operation issued to the VSU. Measured at issue time." }, { "EventCode": "0x2505C", "EventName": "PM_VSU_ISSUE", "BriefDescription": "At least one VSU instruction was issued to one of the VSU pipes. Up to 4 per cycle. Includes fixed point operations." }, { "EventCode": "0x2F054", "EventName": "PM_DISP_SS1_2_INSTR_CYC", "BriefDescription": "Cycles in which Superslice 1 dispatches either 1 or 2 instructions." }, { "EventCode": "0x2F056", "EventName": "PM_DISP_SS1_4_INSTR_CYC", "BriefDescription": "Cycles in which Superslice 1 dispatches either 3 or 4 instructions." }, { "EventCode": "0x2006C", "EventName": "PM_RUN_CYC_SMT4_MODE", "BriefDescription": "Cycles when this thread's run latch is set and the core is in SMT4 mode." }, { "EventCode": "0x201E0", "EventName": "PM_MRK_DATA_FROM_MEMORY", "BriefDescription": "The processor's data cache was reloaded from local, remote, or distant memory due to a demand miss for a marked load." }, { "EventCode": "0x201E4", "EventName": "PM_MRK_DATA_FROM_L3MISS", "BriefDescription": "The processor's L1 data cache was reloaded from beyond the local core's L3 due to a demand miss for a marked instruction." }, { "EventCode": "0x201E8", "EventName": "PM_THRESH_EXC_512", "BriefDescription": "Threshold counter exceeded a value of 512." }, { "EventCode": "0x200F2", "EventName": "PM_INST_DISP", "BriefDescription": "PowerPC instruction dispatched." }, { "EventCode": "0x30132", "EventName": "PM_MRK_VSU_FIN", "BriefDescription": "VSU marked instruction finished. Excludes simple FX instructions issued to the Store Unit." }, { "EventCode": "0x30038", "EventName": "PM_EXEC_STALL_DMISS_LMEM", "BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from the local memory, local OpenCAPI cache, or local OpenCAPI memory." }, { "EventCode": "0x3F04A", "EventName": "PM_LSU_ST5_FIN", "BriefDescription": "LSU Finished an internal operation in ST2 port." }, { "EventCode": "0x3405A", "EventName": "PM_PRIVILEGED_INST_CMPL", "BriefDescription": "PowerPC instruction completed while the thread was in Privileged state." }, { "EventCode": "0x3F150", "EventName": "PM_MRK_ST_DRAIN_CYC", "BriefDescription": "Cycles in which the marked store drained from the core to the L2." }, { "EventCode": "0x3F054", "EventName": "PM_DISP_SS0_4_INSTR_CYC", "BriefDescription": "Cycles in which Superslice 0 dispatches either 3 or 4 instructions." }, { "EventCode": "0x3F056", "EventName": "PM_DISP_SS0_8_INSTR_CYC", "BriefDescription": "Cycles in which Superslice 0 dispatches either 5, 6, 7 or 8 instructions." }, { "EventCode": "0x30162", "EventName": "PM_MRK_ISSUE_DEPENDENT_LOAD", "BriefDescription": "The marked instruction was dependent on a load. It is eligible for issue kill." }, { "EventCode": "0x40114", "EventName": "PM_MRK_START_PROBE_NOP_DISP", "BriefDescription": "Marked Start probe nop dispatched. Instruction AND R0,R0,R0." }, { "EventCode": "0x4001C", "EventName": "PM_VSU_FIN", "BriefDescription": "VSU instruction finished." }, { "EventCode": "0x4C01A", "EventName": "PM_EXEC_STALL_DMISS_OFF_NODE", "BriefDescription": "Cycles in which the oldest instruction in the pipeline was waiting for a load miss to resolve from a distant chip." }, { "EventCode": "0x4D012", "EventName": "PM_PMC3_SAVED", "BriefDescription": "The conditions for the speculative event selected for PMC3 are met and PMC3 is charged." }, { "EventCode": "0x4D022", "EventName": "PM_HYPERVISOR_INST_CMPL", "BriefDescription": "PowerPC instruction completed while the thread was in hypervisor state." }, { "EventCode": "0x4D026", "EventName": "PM_ULTRAVISOR_CYC", "BriefDescription": "Cycles when the thread is in Ultravisor state. MSR[S HV PR]=110." }, { "EventCode": "0x4D028", "EventName": "PM_PRIVILEGED_CYC", "BriefDescription": "Cycles when the thread is in Privileged state. MSR[S HV PR]=x00." }, { "EventCode": "0x40030", "EventName": "PM_INST_FIN", "BriefDescription": "Instruction finished." }, { "EventCode": "0x44146", "EventName": "PM_MRK_STCX_CORE_CYC", "BriefDescription": "Cycles spent in the core portion of a marked STCX instruction. It starts counting when the instruction is decoded and stops counting when it drains into the L2." }, { "EventCode": "0x44054", "EventName": "PM_VECTOR_LD_CMPL", "BriefDescription": "Vector load instruction completed." }, { "EventCode": "0x45054", "EventName": "PM_FMA_CMPL", "BriefDescription": "Two floating point instruction completed (FMA class of instructions: fmadd, fnmadd, fmsub, fnmsub). Scalar instructions only." }, { "EventCode": "0x45056", "EventName": "PM_SCALAR_FLOP_CMPL", "BriefDescription": "Scalar floating point instruction completed." }, { "EventCode": "0x4505C", "EventName": "PM_MATH_FLOP_CMPL", "BriefDescription": "Math floating point instruction completed." }, { "EventCode": "0x4D05E", "EventName": "PM_BR_CMPL", "BriefDescription": "A branch completed. All branches are included." }, { "EventCode": "0x4E15E", "EventName": "PM_MRK_INST_FLUSHED", "BriefDescription": "The marked instruction was flushed." }, { "EventCode": "0x401E6", "EventName": "PM_MRK_INST_FROM_L3MISS", "BriefDescription": "The processor's instruction cache was reloaded from beyond the local core's L3 due to a demand miss for a marked instruction." }, { "EventCode": "0x401E8", "EventName": "PM_MRK_DATA_FROM_L2MISS", "BriefDescription": "The processor's L1 data cache was reloaded from a source beyond the local core's L2 due to a demand miss for a marked instruction." }, { "EventCode": "0x400F0", "EventName": "PM_LD_DEMAND_MISS_L1_FIN", "BriefDescription": "Load missed L1, counted at finish time." }, { "EventCode": "0x400FA", "EventName": "PM_RUN_INST_CMPL", "BriefDescription": "PowerPC instruction completed while the run latch is set." } ]