Micrel KSZ9021 Gigabit Ethernet PHY
Some boards require special tuning values, particularly when it comes to
clock delays. You can specify clock delay values by adding
micrel-specific properties to an Ethernet OF device node.
All skew control options are specified in picoseconds. The minimum
value is 0, and the maximum value is 3000.
Optional properties:
- rxc-skew-ps : Skew control of RXC pad
- rxdv-skew-ps : Skew control of RX CTL pad
- txc-skew-ps : Skew control of TXC pad
- txen-skew-ps : Skew control of TX_CTL pad
- rxd0-skew-ps : Skew control of RX data 0 pad
- rxd1-skew-ps : Skew control of RX data 1 pad
- rxd2-skew-ps : Skew control of RX data 2 pad
- rxd3-skew-ps : Skew control of RX data 3 pad
- txd0-skew-ps : Skew control of TX data 0 pad
- txd1-skew-ps : Skew control of TX data 1 pad
- txd2-skew-ps : Skew control of TX data 2 pad
- txd3-skew-ps : Skew control of TX data 3 pad
Examples:
/* Attach to an Ethernet device with autodetected PHY */
&enet {
rxc-skew-ps = <3000>;
rxdv-skew-ps = <0>;
txc-skew-ps = <3000>;
txen-skew-ps = <0>;
status = "okay";
};
/* Attach to an explicitly-specified PHY */
mdio {
phy0: ethernet-phy@0 {
rxc-skew-ps = <3000>;
rxdv-skew-ps = <0>;
txc-skew-ps = <3000>;
txen-skew-ps = <0>;
reg = <0>;
};
};
ethernet@70000 {
status = "okay";
phy = <&phy0>;
phy-mode = "rgmii-id";
};
|