From 3443f18dc9ab8950071d6299c7a5da86055f3318 Mon Sep 17 00:00:00 2001 From: Max Krummenacher Date: Thu, 19 Jan 2023 15:51:24 +0000 Subject: [PATCH] isp-imx: start_isp: don't report error if no camera is configured The script currently returns '6' when no known camera is configured in the device tree. The end result is that the systemd imx8-isp.service goes to the failed state. Return '0' in that case as obviously the device tree doesn't have a camera configured and the service is not needed. Related-to: ELB-5002 Signed-off-by: Max Krummenacher --- imx/start_isp.sh | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/imx/start_isp.sh b/imx/start_isp.sh index 95cbc19..d603f8f 100755 --- a/imx/start_isp.sh +++ b/imx/start_isp.sh @@ -74,5 +74,5 @@ elif [ $NR_DEVICE_TREE_OS08A20 -eq 2 ]; then else # no device tree found exit with code no device or address echo "No device tree found for Basler camera or os08a20, check dtb file!" >&2 - exit 6 + exit 0 fi -- 2.35.3