authorMark Tomlinson <mark.tomlinson@alliedtelesis.co.nz>2025-01-20 14:59:41 +1300
committerTom Rini <trini@konsulko.com>2025-01-26 11:33:13 -0600
commit0e4c345ecf653aab7684ef6ab0a9e794e8659f5f (patch)
treea88fe8f53030680e93f9e4ed63d3ccbe2fef6cd7 /common/bloblist.c
parentd86da7e2bd6ae89360ff020565f9bf82712d688e (diff)
drivers: rtc: max313xx: Ensure correct date is read after setting
When setting the time on the MAX31343, the time is not updated for one second, and reading the time in this interval will give the old time. Wait one second after writing so that the date command will show the correct time when setting the clock. Signed-off-by: Mark Tomlinson <mark.tomlinson@alliedtelesis.co.nz> Cc: Chris Packham <judge.packham@gmail.com> Reviewed-by: Chris Packham <judge.packham@gmail.com>