power: supply: ab8500: Preserve battery termination current
The battery-info parser uses a negative value for an unspecified termination current. Testing the value as a boolean instead replaces every valid positive current from the battery description with 200 mA. Apply the default only when the property is unspecified so batteries retain their described charging termination current. Fixes: 9c20899da46b ("power: supply: ab8500: Standardize termination current") Assisted-by: LLM Signed-off-by: Linus Walleij <linusw@kernel.org> Link: https://patch.msgid.link/20260916-ab8500-charging-v1-6-e986ed321cc6@kernel.org Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
-rw-r--r--drivers/power/supply/ab8500_bmdata.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/power/supply/ab8500_bmdata.c b/drivers/power/supply/ab8500_bmdata.c
index d7fd2d313ff1..0f04893d6bf9 100644
--- a/drivers/power/supply/ab8500_bmdata.c
+++ b/drivers/power/supply/ab8500_bmdata.c
@@ -173,7 +173,7 @@ int ab8500_bm_of_probe(struct power_supply *psy,
if (bi->constant_charge_voltage_max_uv < 0)
bi->constant_charge_voltage_max_uv = 4100000;
- if (bi->charge_term_current_ua)
+ if (bi->charge_term_current_ua < 0)
/* Charging stops when we drop below this current */
bi->charge_term_current_ua = 200000;