summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorKornel Dulęba <korneld@google.com>2025-05-28 11:23:29 +0000
committerSebastian Reichel <sebastian.reichel@collabora.com>2025-06-22 02:54:46 +0200
commit3f87baacea4d185071655f9b0baf07abb6237fcd (patch)
tree43205bb6d92be11777788fa58bc5a640b4c0fbcb
parent6aa1c3a72b99abeb7ddc649047073d701ede2c91 (diff)
power: supply: qcom_battmgr: Report battery capacity
Battery charge can be reported in several different ways. One of them is is charge percentage referred to as POWER_SUPPLY_PROP_CAPACITY in the power supply API. Currently the driver reports the capacity in this way on SM8350, but not on the newer variants referred to as SC8280XP in the driver. Although this is not a bug in itself, not reporting the percentage can confuse some userspace consumers. Mimic what is done in the ACPI driver (drivers/acpi/battery.c) and calculate the percentage capacity by dividing the current charge value by the full charge. Signed-off-by: Kornel Dulęba <korneld@google.com> Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com> Link: https://lore.kernel.org/r/20250528112328.1640743-2-korneld@google.com Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
-rw-r--r--drivers/power/supply/qcom_battmgr.c23
1 files changed, 23 insertions, 0 deletions
diff --git a/drivers/power/supply/qcom_battmgr.c b/drivers/power/supply/qcom_battmgr.c
index fe27676fbc7c..33a70f3d72bc 100644
--- a/drivers/power/supply/qcom_battmgr.c
+++ b/drivers/power/supply/qcom_battmgr.c
@@ -577,6 +577,8 @@ static int qcom_battmgr_bat_get_property(struct power_supply *psy,
val->intval = battmgr->status.capacity;
break;
case POWER_SUPPLY_PROP_CAPACITY:
+ if (battmgr->status.percent == (unsigned int)-1)
+ return -ENODATA;
val->intval = battmgr->status.percent;
break;
case POWER_SUPPLY_PROP_TEMP:
@@ -617,6 +619,7 @@ static const enum power_supply_property sc8280xp_bat_props[] = {
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_TECHNOLOGY,
+ POWER_SUPPLY_PROP_CAPACITY,
POWER_SUPPLY_PROP_CYCLE_COUNT,
POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
POWER_SUPPLY_PROP_VOLTAGE_NOW,
@@ -1063,6 +1066,26 @@ static void qcom_battmgr_sc8280xp_callback(struct qcom_battmgr *battmgr,
battmgr->ac.online = source == BATTMGR_CHARGING_SOURCE_AC;
battmgr->usb.online = source == BATTMGR_CHARGING_SOURCE_USB;
battmgr->wireless.online = source == BATTMGR_CHARGING_SOURCE_WIRELESS;
+ if (battmgr->info.last_full_capacity != 0) {
+ /*
+ * 100 * battmgr->status.capacity can overflow a 32bit
+ * unsigned integer. FW readings are in m{W/A}h, which
+ * are multiplied by 1000 converting them to u{W/A}h,
+ * the format the power_supply API expects.
+ * To avoid overflow use the original value for dividend
+ * and convert the divider back to m{W/A}h, which can be
+ * done without any loss of precision.
+ */
+ battmgr->status.percent =
+ (100 * le32_to_cpu(resp->status.capacity)) /
+ (battmgr->info.last_full_capacity / 1000);
+ } else {
+ /*
+ * Let the sysfs handler know no data is available at
+ * this time.
+ */
+ battmgr->status.percent = (unsigned int)-1;
+ }
break;
case BATTMGR_BAT_DISCHARGE_TIME:
battmgr->status.discharge_time = le32_to_cpu(resp->time);