summaryrefslogtreecommitdiff
path: root/kernel/power/em_netlink_autogen.c
diff options
context:
space:
mode:
authorChangwoo Min <changwoo@igalia.com>2026-01-08 14:32:10 +0900
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>2026-01-09 21:44:46 +0100
commitcaa07a815d6ee32586beb66f67e7e3c103a02efd (patch)
tree73e9c905a7f880c561c3bd2853964d1116859d76 /kernel/power/em_netlink_autogen.c
parentebabc32ddb84caf2c018ae6aeca2ca2989a8056b (diff)
PM: EM: Rename em.yaml to dev-energymodel.yaml
The EM YNL specification used many acronyms, including ‘em’, ‘pd’, ‘ps’, etc. While the acronyms are short and convenient, they could be confusing. So, let’s spell them out to be more specific. The following changes were made in the spec. Note that the protocol name cannot exceed GENL_NAMSIZ (16). em -> dev-energymodel pds -> perf-domains pd -> perf-domain pd-id -> perf-domain-id pd-table -> perf-table ps -> perf-state get-pds -> get-perf-domains get-pd-table -> get-perf-table pd-created -> perf-domain-created pd-updated -> perf-domain-updated pd-deleted -> perf-domain-deleted In addition. doc strings were added to the spec. based on the comments in energy_model.h. Two flag attributes (perf-state-flags and perf-domain-flags) were added for easily interpreting the bit flags. Finally, the autogenerated files and em_netlink.c were updated accordingly to reflect the name changes. Suggested-by: Donald Hunter <donald.hunter@gmail.com> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Reviewed-by: Donald Hunter <donald.hunter@gmail.com> Signed-off-by: Changwoo Min <changwoo@igalia.com> Link: https://patch.msgid.link/20260108053212.642478-3-changwoo@igalia.com Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'kernel/power/em_netlink_autogen.c')
-rw-r--r--kernel/power/em_netlink_autogen.c44
1 files changed, 22 insertions, 22 deletions
diff --git a/kernel/power/em_netlink_autogen.c b/kernel/power/em_netlink_autogen.c
index ceb3b2bb6ebe..44acef0e7df2 100644
--- a/kernel/power/em_netlink_autogen.c
+++ b/kernel/power/em_netlink_autogen.c
@@ -1,6 +1,6 @@
// SPDX-License-Identifier: ((GPL-2.0 WITH Linux-syscall-note) OR BSD-3-Clause)
/* Do not edit directly, auto-generated from: */
-/* Documentation/netlink/specs/em.yaml */
+/* Documentation/netlink/specs/dev-energymodel.yaml */
/* YNL-GEN kernel source */
/* To regenerate run: tools/net/ynl/ynl-regen.sh */
@@ -9,41 +9,41 @@
#include "em_netlink_autogen.h"
-#include <uapi/linux/energy_model.h>
+#include <uapi/linux/dev_energymodel.h>
-/* EM_CMD_GET_PD_TABLE - do */
-static const struct nla_policy em_get_pd_table_nl_policy[EM_A_PD_TABLE_PD_ID + 1] = {
- [EM_A_PD_TABLE_PD_ID] = { .type = NLA_U32, },
+/* DEV_ENERGYMODEL_CMD_GET_PERF_TABLE - do */
+static const struct nla_policy dev_energymodel_get_perf_table_nl_policy[DEV_ENERGYMODEL_A_PERF_TABLE_PERF_DOMAIN_ID + 1] = {
+ [DEV_ENERGYMODEL_A_PERF_TABLE_PERF_DOMAIN_ID] = { .type = NLA_U32, },
};
-/* Ops table for em */
-static const struct genl_split_ops em_nl_ops[] = {
+/* Ops table for dev_energymodel */
+static const struct genl_split_ops dev_energymodel_nl_ops[] = {
{
- .cmd = EM_CMD_GET_PDS,
- .doit = em_nl_get_pds_doit,
+ .cmd = DEV_ENERGYMODEL_CMD_GET_PERF_DOMAINS,
+ .doit = dev_energymodel_nl_get_perf_domains_doit,
.flags = GENL_CMD_CAP_DO,
},
{
- .cmd = EM_CMD_GET_PD_TABLE,
- .doit = em_nl_get_pd_table_doit,
- .policy = em_get_pd_table_nl_policy,
- .maxattr = EM_A_PD_TABLE_PD_ID,
+ .cmd = DEV_ENERGYMODEL_CMD_GET_PERF_TABLE,
+ .doit = dev_energymodel_nl_get_perf_table_doit,
+ .policy = dev_energymodel_get_perf_table_nl_policy,
+ .maxattr = DEV_ENERGYMODEL_A_PERF_TABLE_PERF_DOMAIN_ID,
.flags = GENL_CMD_CAP_DO,
},
};
-static const struct genl_multicast_group em_nl_mcgrps[] = {
- [EM_NLGRP_EVENT] = { "event", },
+static const struct genl_multicast_group dev_energymodel_nl_mcgrps[] = {
+ [DEV_ENERGYMODEL_NLGRP_EVENT] = { "event", },
};
-struct genl_family em_nl_family __ro_after_init = {
- .name = EM_FAMILY_NAME,
- .version = EM_FAMILY_VERSION,
+struct genl_family dev_energymodel_nl_family __ro_after_init = {
+ .name = DEV_ENERGYMODEL_FAMILY_NAME,
+ .version = DEV_ENERGYMODEL_FAMILY_VERSION,
.netnsok = true,
.parallel_ops = true,
.module = THIS_MODULE,
- .split_ops = em_nl_ops,
- .n_split_ops = ARRAY_SIZE(em_nl_ops),
- .mcgrps = em_nl_mcgrps,
- .n_mcgrps = ARRAY_SIZE(em_nl_mcgrps),
+ .split_ops = dev_energymodel_nl_ops,
+ .n_split_ops = ARRAY_SIZE(dev_energymodel_nl_ops),
+ .mcgrps = dev_energymodel_nl_mcgrps,
+ .n_mcgrps = ARRAY_SIZE(dev_energymodel_nl_mcgrps),
};