diff options
author | Francesco Dolcini <francesco.dolcini@toradex.com> | 2021-10-07 18:45:35 +0200 |
---|---|---|
committer | Hiago De Franco <hiago.franco@toradex.com> | 2023-06-29 12:14:22 +0200 |
commit | ddc6ca4d76ea764aaec9837fb9c82297473e6edc (patch) | |
tree | 4646c5d74b899d055422a74fed7f80e6492e6b8a /scripts/extract-ikconfig | |
parent | e6282b64a8347281312635c9b9145eea44ef14cb (diff) |
net: phy: micrel: ksz9131 led errata workaroundtoradex_5.15-2.1.x-imx
Micrel KSZ9131 PHY LED behavior is not correct when configured in
Individual Mode, LED1 (Activity LED) is in the ON state when there is
no-link.
Workaround this by setting bit 9 of register 0x1e after verifying that
the LED configuration is Individual Mode.
This issue is described in KSZ9131RNX Silicon Errata DS80000693B [*]
and according to that it will not be corrected in a future silicon
revision.
[*] https://ww1.microchip.com/downloads/en/DeviceDoc/KSZ9131RNX-Silicon-Errata-and-Data-Sheet-Clarification-80000863B.pdf
Upstream-Status: Backport [0316c7e66bbd16cf2d01a4e2f5afa6afb01278f2]
Signed-off-by: Francesco Dolcini <francesco.dolcini@toradex.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Philippe Schenker <philippe.schenker@toradex.com>
Diffstat (limited to 'scripts/extract-ikconfig')
0 files changed, 0 insertions, 0 deletions