authorSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>2026-11-04 08:53:19 -0800
committerJonathan Cameron <jonathan.cameron@oss.qualcomm.com>2026-11-11 02:53:02 +0000
commit79c8dffd84e9784ec05bea68dbe5e71f7ec9941a (patch)
treef0bf1efef06a2e9ff5804ff7c32f7e5984404478 /scripts
parentd32bf759801e6df23038dc834622a122ec76a4dd (diff)
iio: hid-sensors: fix fractional part for unit exponents -7 and -8
split_micro_fraction() scales the remainder to micro units by multiplying it by 10^(6 - exp). The unit exponent of a HID field goes down to -8, so exp can be 7 or 8 here. Then the argument of int_pow() is negative, which the unsigned parameter turns into a huge power of ten: 0 modulo 2^64. As a result, the fractional part of a value read from the hysteresis attributes is always reported as 0. Divide by 10^(exp - 6) in these two cases. This matches the reverse conversion in convert_to_vtf_format(). Fixes: 73c6768b710a ("iio: hid-sensors: Common attribute and trigger") Cc: stable@vger.kernel.org Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Tested-by: Semyon Maryasin <simeon@maryasin.name> Signed-off-by: Jonathan Cameron <jonathan.cameron@oss.qualcomm.com>