authorMarek Vasut <marek.vasut+renesas@mailbox.org>2026-07-14 15:04:58 +0200
committerGeert Uytterhoeven <geert+renesas@glider.be>2026-09-14 10:09:57 +0200
commit971dcce966f519dc79cbd43d288587d13bdc6d58 (patch)
treefbe7bf36d3986dd9d0c433a4561d234c2bb4aacd /tools/perf/scripts/python/bin
parent0c3c3251e04cd9f5d45f75d8d10b8f17a417bdcc (diff)
arm64: dts: renesas: hihope-rzg2-ex: Specify ethernet PHY reset timings
The RTL8211E reference manual [1] page 38 chapter 7.16. PHY Reset (Hardware Reset) states that the PHYRSTB pin must be asserted low for at least 10ms (Tgap in Figure 10) and the system must wait at minimum 30ms (for internal circuits settle time) before accessing the PHY registers. Use 15ms and 35ms respectively to provide some additional margin. [1] https://files.pine64.org/doc/datasheet/pine64/rtl8211e%28g%29-vb%28vl%29-cg_datasheet_1.6.pdf Signed-off-by: Marek Vasut <marek.vasut+renesas@mailbox.org> Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> Link: https://patch.msgid.link/20260714130515.11262-2-marek.vasut+renesas@mailbox.org Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>