summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/bin
diff options
context:
space:
mode:
authorMarek Vasut <marek.vasut+renesas@mailbox.org>2026-07-14 15:03:58 +0200
committerGeert Uytterhoeven <geert+renesas@glider.be>2026-09-14 10:09:49 +0200
commitdbd554cf1da949172d966474d53e99a298685ede (patch)
tree6853fac602ed6ab2e16146345a830f2dad97a5f5 /tools/perf/scripts/python/bin
parent26d255772917b3d6236acb8c2a1187d0df9f2d2e (diff)
ARM: dts: renesas: gose: Specify ethernet PHY reset timings
The KSZ8041RNL reference manual [1] DS00002245C page 47 TABLE 7-10: POWER-UP/RESET TIMING PARAMETERS does not indicate how long should the system wait after deassertion of the PHY reset and before start of communication with the PHY via MDIO. Opt for the same value as used for KSZ9031RNX, which is 300 us. The KSZ8041RNL reference manual [1] DS00002245C page 47 TABLE 7-10: POWER-UP/RESET TIMING PARAMETERS row tSR Stable supply voltages to reset high is at minimum 10 ms. Set the DT property reset-assert-us to 10ms because the KSZ8041RNL RM does not explicitly spell out how long the reset has to be asserted, but this at least covers the worst case scenario. [1] https://ww1.microchip.com/downloads/aemDocuments/documents/UNG/ProductDocuments/DataSheets/KSZ8041NL-RNL-Data-Sheet-DS00002245.pdf Signed-off-by: Marek Vasut <marek.vasut+renesas@mailbox.org> Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> Link: https://patch.msgid.link/20260714130429.11214-5-marek.vasut+renesas@mailbox.org Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Diffstat (limited to 'tools/perf/scripts/python/bin')
0 files changed, 0 insertions, 0 deletions