diff options
| author | Armin Wolf <W_Armin@gmx.de> | 2026-08-07 01:38:17 +0200 |
|---|---|---|
| committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2026-09-09 16:22:51 +0200 |
| commit | 21af603b6509e1e2297de5c159317639477dcbf3 (patch) | |
| tree | 1833f38bf79a4b6e25e669a81c00513c5126722f /tools/perf/scripts/python | |
| parent | df2908090cda368b01ff43709f51890076c56157 (diff) | |
ACPI: battery: Fix bogus cycle count values on systems without _BIX
Devices supporting only the legacy _BIF ACPI control method cannot
know the cycle count of the associated battery, so cycle_count always
remains 0. Claiming support for POWER_SUPPLY_PROP_CYCLE_COUNT on
such devices can thus mislead userspace applications and prevents
power supply extensions from supplying correct cycle count values.
Fix this by not claiming support for POWER_SUPPLY_PROP_CYCLE_COUNT
on devices without _BIX.
Signed-off-by: Armin Wolf <W_Armin@gmx.de>
Link: https://patch.msgid.link/20260806233817.622975-1-W_Armin@gmx.de
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Diffstat (limited to 'tools/perf/scripts/python')
0 files changed, 0 insertions, 0 deletions