net: dsa: mt7530: preserve VLAN tags on trapped link-local frames
The BPC, RGAC1 and RGAC2 registers control the handling of link-local frames with reserved MAC DAs (01:80:C2:00:00:0x). These frames are correctly trapped to the CPU port, but the egress VLAN tag attribute was set to MT7530_VLAN_EG_UNTAGGED which causes the switch to strip any VLAN tags from trapped frames before they reach the CPU. This causes VLAN-tagged link-local frames (STP BPDUs, LLDP, PTP Peer Delay Requests) to arrive at the CPU without their VLAN tag, so they are delivered to the base network interface instead of the VLAN sub-interface. The DSA local_termination selftest confirms this: all link-local protocol tests on VLAN upper interfaces fail. Set the EG_TAG attribute to MT7530_VLAN_EG_DISABLED (system default) so that the switch does not modify VLAN tags in trapped frames. This way VLAN-tagged frames retain their original tag and are delivered to the correct VLAN sub-interface, matching the behavior of non-trapped frames which pass through without VLAN tag modification. Fixes: 69ddba9d170b ("net: dsa: mt7530: fix handling of all link-local frames") Signed-off-by: Daniel Golle <daniel@makrotopia.org> Acked-by: Chester A. Unal <chester.a.unal@arinc9.com> Link: https://patch.msgid.link/891e0cd34db2a5fe20ceb73283a81fb5f71427ca.1778766629.git.daniel@makrotopia.org Signed-off-by: Paolo Abeni <pabeni@redhat.com>
Diffstat (limited to 'tools/testing')
0 files changed, 0 insertions, 0 deletions